中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The effect analysis of conic coefficient error based on data measured from Talysurf and simulation of Zernike coefficients

文献类型:会议论文

作者Jiang, Kai; Liu, Kai; Song, Chong; Qiu, Peng; Wang, Peng; Li, Gang
出版日期2016
会议名称8th international symposium on advanced optical manufacturing and testing technology (aomatt) - optical test, measurement technology, and equipment
会议日期2016-04-26
会议地点suzhou, peoples r china
关键词conic coefficient contourgraph Zernike coefficients optical design
卷号9684
通讯作者jiang, k (reprint author), chinese acad sci, xian inst opt & precis mech, photoelect track & measurement technol res dept, xian 710119, shaanxi, peoples r china.
英文摘要

derivation of the conic coefficient error of practical aspheric optic surface is quite significant to aspheric machining accuracy, optical system imaging quality analysis and decomposition analysis of optical lenses. the primary mirror of r-c telescope system was tested by taylor hobson talysurf. the practical surface was fitted using zernike polynomials based on the date measured from talysurf. though taking the zernike coefficients into the optical system, the effect of the aberration which was brought by optical machining to the optical system imaging quality was obtained. the analysis shows that the spherical aberration was brought into the optical system because of the figure error of the primary mirror. and the value of the spherical aberration was same to the practical alignment result. then the conicoid aspherical degree of the primary mirror was tested by the talysurf. the machining deviation of the conic coefficient was gotten though comparing the conicoid aspherical degree of the practical primary mirror with that of the perfect primary mirror. the practical conic coefficient was calculated by the deviation. taking the practical conic coefficient into the r-c telescope system, the degradation of the optical system imaging quality was known. also the spherical aberration was brought into the optical system. experimental results show that the value of the spherical aberration analyzed by the two methods is same and consist with the practical alignment result. that is to say that the conic coefficient changed due to machining error of the conicoid aspherical degree. because of the change the spherical aberration was attached to primary mirror. and which caused the optical system imaging quality declined. finally, corrector was designed to balance the spherical aberration of the primary mirror. ensure that the optical system imaging quality meet the requirement.

收录类别EI ; ISTP
产权排序1
会议录8th international symposium on advanced optical manufacturing and testing technology: optical test, measurement technology, and equipment
会议录出版者spie-int soc optical engineering
学科主题materials science, characterization & testing ; optics
会议录出版地bellingham
语种英语
ISSN号0277-786x
ISBN号978-1-62841-919-1
源URL[http://ir.opt.ac.cn/handle/181661/28457]  
专题西安光学精密机械研究所_光电测量技术实验室
作者单位Chinese Acad Sci, Xian Inst Opt & Precis Mech, Photoelect Track & Measurement Technol Res Dept, Xian 710119, Shaanxi, Peoples R China
推荐引用方式
GB/T 7714
Jiang, Kai,Liu, Kai,Song, Chong,et al. The effect analysis of conic coefficient error based on data measured from Talysurf and simulation of Zernike coefficients[C]. 见:8th international symposium on advanced optical manufacturing and testing technology (aomatt) - optical test, measurement technology, and equipment. suzhou, peoples r china. 2016-04-26.

入库方式: OAI收割

来源:西安光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。