Integrated measurement system with galileo telescope combined with cylindrical lens
文献类型:期刊论文
作者 | Liu, Ai-Min1,2![]() ![]() ![]() |
刊名 | guangzi xuebao/acta photonica sinica
![]() |
出版日期 | 2016-11-01 |
卷号 | 45期号:11 |
关键词 | Fits and tolerances Light sources Optical design Optical systems Telescopes |
ISSN号 | 10044213 |
其他题名 | 伽利略望远镜与柱面镜组合式长焦综合测量系统 |
产权排序 | 1 |
英文摘要 | to achieve azimuth and height measurement of a slowly moving point in a certain distance and wide field of view, a combined long-focal-length cylindrical lens measurement system was built. a point shape reticle, a long-focal-length optical system formed by a galileo telescope combined with cylindrical lens and two orthogonal linear array ccd were utilized. there isn't a real middle image plane in the combined long-focal-length optical system with a relatively short optical length. the front part of the system is a galileo telescope, and its focal power is approximate to 0. within a measurement range, some parameters, such as the value of the angular magnification and diameter of the front part, should be properly selected, making the linear image from different field orthogonal to the two linear ccd. through targeted lens system design optimization, proper selection of merit function, and tolerance analysis of the alignment and measurement principle, the acurracy of azimuth measurement of this system is less than ±2.5′, within field of view of 1.5°×1.5°, at the measurement distance of 10 m, additionally with relatiely small system length, and relatively loose tolerance. the proposed system can solve the problem of the limited size of light source cooperation target, making a low cost and large size photo-electronic detector. © 2016, science press. all right reserved. |
学科主题 | light/optics ; optical devices and systems |
收录类别 | EI |
语种 | 中文 |
源URL | [http://ir.opt.ac.cn/handle/181661/28529] ![]() |
专题 | 西安光学精密机械研究所_光学定向与测量技术研究室 |
作者单位 | 1.Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, 710119, China 2.University of Chinese Academy of Sciences, Beijing, 100039, China |
推荐引用方式 GB/T 7714 | Liu, Ai-Min,Gao, Li-Min,Xiao, Mao-Sen,et al. Integrated measurement system with galileo telescope combined with cylindrical lens[J]. guangzi xuebao/acta photonica sinica,2016,45(11). |
APA | Liu, Ai-Min,Gao, Li-Min,Xiao, Mao-Sen,Lu, Wei-Guo,&Wang, Hai-Xia.(2016).Integrated measurement system with galileo telescope combined with cylindrical lens.guangzi xuebao/acta photonica sinica,45(11). |
MLA | Liu, Ai-Min,et al."Integrated measurement system with galileo telescope combined with cylindrical lens".guangzi xuebao/acta photonica sinica 45.11(2016). |
入库方式: OAI收割
来源:西安光学精密机械研究所
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。