中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Direct and indirect fluorescent detection of tetracyclines using dually emitting carbon dots

文献类型:期刊论文

作者Qu, Fei1,2; Sun, Zhe1,2; Liu, Dongya1,2; Zhao, Xianen1,2; You, Jinmao1,2,3
刊名microchimica acta
出版日期2016-09-01
卷号183期号:9页码:2547-2553
关键词Tetracycline Oxytetracycline Chlortetracycline Doxycycline Fluorometry Quenching
英文摘要the authors describe dual-emission carbon nanodots containing blue emitters (be; peak emission at 385nm under 315 nm excitation) and yellow emitters (ye; peak emission at 530 nm under 365nm excitation), and how they can be applied to direct and indirect determination of tetracyclines (tcs). the direct detection scheme is based on the finding that tetracycline (tet), oxytetracycline, chlortetracycline and doxycycline quench the two emissions of the carbon dots. while direct determination is rapid and convenient, it cannot differentiate between tcs. the indirect detection scheme, in contrast, is based on the finding that al (iii) ions enhance the fluorescence of the ye in the carbon dots, and that they cause a blue shift in emission. it is, however, known that tet forms a strong complex with al (iii), and this can inhibit the interaction between al (iii) and the ye, so that the fluorescence of ye is not enhanced and blue-shifted by al (iii) in the presence of tet. this finding is exploited in a fluorescence turn-on/off assay for tet that can distinguish tet from other tcs. the linear range of indirect determination for tet extends from 1 nm to 30 mu m, and the limit of detection is 0.52 nm. the indirect method was successfully applied to the determination of tet in spiked milk, fish and pork, and recoveries ranged from 91.7 to 102 %.
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, analytical
研究领域[WOS]chemistry
关键词[WOS]enhanced-fluorescence ; quantum dots ; oxytetracycline ; residues ; probes ; nanoparticles ; copper(ii) ; nanodots ; ions ; milk
收录类别SCI
语种英语
WOS记录号WOS:000381401300008
源URL[http://ir.nwipb.ac.cn/handle/363003/6428]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位1.Qufu Normal Univ, Key Lab Life Organ Anal, Qufu 273165, Shandong, Peoples R China
2.Qufu Normal Univ, Key Lab Pharmaceut Intermediates & Anal Nat Med, Qufu 273165, Shandong, Peoples R China
3.Chinese Acad Sci, Northwest Inst Plateau Biol, Xining 810001, Peoples R China
推荐引用方式
GB/T 7714
Qu, Fei,Sun, Zhe,Liu, Dongya,et al. Direct and indirect fluorescent detection of tetracyclines using dually emitting carbon dots[J]. microchimica acta,2016,183(9):2547-2553.
APA Qu, Fei,Sun, Zhe,Liu, Dongya,Zhao, Xianen,&You, Jinmao.(2016).Direct and indirect fluorescent detection of tetracyclines using dually emitting carbon dots.microchimica acta,183(9),2547-2553.
MLA Qu, Fei,et al."Direct and indirect fluorescent detection of tetracyclines using dually emitting carbon dots".microchimica acta 183.9(2016):2547-2553.

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。