The Design and Test of a Cryogenic Micro-Displacement Actuator
文献类型:期刊论文
作者 | Bai Qingshun; Wang Qun; Zhang Qingchun; Liang Yingchun; Lou Zheng |
刊名 | Astronomical Research & Technology
![]() |
出版日期 | 2016 |
卷号 | 13期号:2页码:199-204 |
英文摘要 | Taking the polar astronomical telescope as application background, a cryogenic microdisplacement actuator is designed and then tested at room temperature and low temperature environment respectively. Performance parameters of this actuator is acquired. Three kinds of structural forms of long travel high-accuracy micro-displacement actuator are analyzed; the displacement scaling is chosen as the basic structure of this cryogenic micro-displacement actuator. Cryogenic step motor is employed as the drive element, and the screw drive mechanism which contains specific anti-backlash structure is selected as the displacement scaling mechanism. This design develops a micro-displacement actuator which maintains satisfactory qualities such as high stiffness,low temperature resistance,compact structure and good leakproofness. Performance tests are also carried out. Test results indicate that the cryogenic micro-displacement actuator can achieve the step accuracy of 1mum 0.082mum at ambient temperature,and its load capacity meets the design requirements; meanwhile,the cryogenic micro-displacement actuator can achieve the step accuracy of 2mum 0.404mum at low temperature. This cryogenic micro-displacement actuator will provide important technical support for the construction of the splicing polar astronomical telescope. |
源URL | [http://libir.pmo.ac.cn/handle/332002/16825] ![]() |
专题 | 紫金山天文台_毫米波和亚毫米波技术实验室 |
推荐引用方式 GB/T 7714 | Bai Qingshun,Wang Qun,Zhang Qingchun,et al. The Design and Test of a Cryogenic Micro-Displacement Actuator[J]. Astronomical Research & Technology,2016,13(2):199-204. |
APA | Bai Qingshun,Wang Qun,Zhang Qingchun,Liang Yingchun,&Lou Zheng.(2016).The Design and Test of a Cryogenic Micro-Displacement Actuator.Astronomical Research & Technology,13(2),199-204. |
MLA | Bai Qingshun,et al."The Design and Test of a Cryogenic Micro-Displacement Actuator".Astronomical Research & Technology 13.2(2016):199-204. |
入库方式: OAI收割
来源:紫金山天文台
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。