Thermodynamic analysis of absorption heat transformers using [mmim]DMP/H2O and [mmim]DMP/CH3OH as working fluids
文献类型:期刊论文
作者 | Chen, Wei1; Liang, Shiqiang2 |
刊名 | APPLIED THERMAL ENGINEERING
![]() |
出版日期 | 2016-04-25 |
卷号 | 99页码:846-856 |
关键词 | [mmim]DMP/H2O [mmim]DMP/CH3OH Absorption heat transformer (AHT) Coefficient of performance (COP) Exergy analysis |
英文摘要 | The thermodynamic performances of absorption heat transformers (AHTs) using [mmim]DMP/H2O and [mmim]DMP/CH3OH as working fluids were numerically analyzed. Variations in coefficients of performance (COPs), exergy efficiencies, and circulation ratios of the [mmim]DMP/H2O and [mmim]DMP/CH3OH AHTs with varying operating temperatures were simulated and compared with those of the LiBr/H2O system. COPs and exergy efficiencies of the [mmim]DMP/H2O and [mmim]DMP/CH3OH AHTs were slightly lower than those of the LiBr/H2O system. But the properties of GTL for [mmim]DMP/H2O and [mmim]DMP/CH3OH systems are superior to the LiBr/H2O system. The exergy losses of each component and the entire system for the three working fluids were calculated and compared. Changes in exergy losses with varying absorption, generation, and evaporation temperatures were analyzed. For the [mmim]DMP/H2O and LiBr/H2O systems, the largest exergy losses were produced in generator and evaporator. For the [mmim]DMP/CH3OH system, the largest exergy losses were produced in generator and absorber. (C) 2016 Elsevier Ltd. All rights reserved. |
WOS标题词 | Science & Technology ; Physical Sciences ; Technology |
类目[WOS] | Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics |
研究领域[WOS] | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
关键词[WOS] | REFRIGERATION SYSTEM ; IONIC LIQUID ; EXPERIMENTAL PERFORMANCE ; EXERGY ANALYSIS ; VAPOR-PRESSURE ; AMMONIA-WATER ; SINGLE-STAGE ; MIXTURE ; CYCLES ; PAIRS |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000373863200087 |
源URL | [http://ir.etp.ac.cn/handle/311046/112503] ![]() |
专题 | 工程热物理研究所_中国科学院工程热物理所(论文库)_期刊论文(SCI) |
作者单位 | 1.Qingdao Univ Sci & Technol, Coll Electromech Engn, Qingdao 266061, Peoples R China 2.Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Wei,Liang, Shiqiang. Thermodynamic analysis of absorption heat transformers using [mmim]DMP/H2O and [mmim]DMP/CH3OH as working fluids[J]. APPLIED THERMAL ENGINEERING,2016,99:846-856. |
APA | Chen, Wei,&Liang, Shiqiang.(2016).Thermodynamic analysis of absorption heat transformers using [mmim]DMP/H2O and [mmim]DMP/CH3OH as working fluids.APPLIED THERMAL ENGINEERING,99,846-856. |
MLA | Chen, Wei,et al."Thermodynamic analysis of absorption heat transformers using [mmim]DMP/H2O and [mmim]DMP/CH3OH as working fluids".APPLIED THERMAL ENGINEERING 99(2016):846-856. |
入库方式: OAI收割
来源:工程热物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。