A new calibration model for pointing a radio telescope that considers nonlinear errors in the azimuth axis

文献类型:期刊论文

作者Kong, De-Qing1; Wang, Song-Gen1,2; Wang, Jin-Qing3; Wang, Min4; Zhang, Hong-Bo1; Kong Deqing; Zhang Hongbo
刊名RESEARCH IN ASTRONOMY AND ASTROPHYSICS
出版日期2014-06-01
卷号14期号:6页码:733-740
关键词telescopes antennas pointing models
英文摘要A new calibration model of a radio telescope that includes pointing error is presented, which considers nonlinear errors in the azimuth axis. For a large radio telescope, in particular for a telescope with a turntable, it is difficult to correct pointing errors using a traditional linear calibration model, because errors produced by the wheel-on-rail or center bearing structures are generally nonlinear. Fourier expansion is made for the oblique error and parameters describing the inclination direction along the azimuth axis based on the linear calibration model, and a new calibration model for pointing is derived. The new pointing model is applied to the 40 m radio telescope administered by Yunnan Observatories, which is a telescope that uses a turntable. The results show that this model can significantly reduce the residual systematic errors due to nonlinearity in the azimuth axis compared with the linear model.
收录类别SCI
语种英语
WOS记录号WOS:000337717100011
源URL[http://ir.bao.ac.cn/handle/114a11/6387]  
专题国家天文台_月球与深空探测研究部
作者单位1.Chinese Acad Sci, Natl Astron Observ, Beijing 100012, Peoples R China
2.Hangzhou Dianzi Univ, Coll Mech Engn, Hangzhou 310018, Zhejiang, Peoples R China
3.Chinese Acad Sci, Shanghai Astron Observ, Shanghai 200030, Peoples R China
4.Chinese Acad Sci, Yunnan Observ, Kunming 650011, Peoples R China
推荐引用方式
GB/T 7714
Kong, De-Qing,Wang, Song-Gen,Wang, Jin-Qing,et al. A new calibration model for pointing a radio telescope that considers nonlinear errors in the azimuth axis[J]. RESEARCH IN ASTRONOMY AND ASTROPHYSICS,2014,14(6):733-740.
APA Kong, De-Qing.,Wang, Song-Gen.,Wang, Jin-Qing.,Wang, Min.,Zhang, Hong-Bo.,...&Zhang Hongbo.(2014).A new calibration model for pointing a radio telescope that considers nonlinear errors in the azimuth axis.RESEARCH IN ASTRONOMY AND ASTROPHYSICS,14(6),733-740.
MLA Kong, De-Qing,et al."A new calibration model for pointing a radio telescope that considers nonlinear errors in the azimuth axis".RESEARCH IN ASTRONOMY AND ASTROPHYSICS 14.6(2014):733-740.

入库方式: OAI收割

来源:国家天文台

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。