中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Effect of different number of diffusion gradient directions on dispersion degree of FA values and its SNR

文献类型:会议论文

作者Zhang, Na; Deng, Zhensheng; Yin, Xiaojuan; Liu, Xin; Zheng, Hairong
出版日期2010
会议名称4th International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2010
会议地点Chengdu, China
英文摘要To study the effect of different number of diffusion gradient directions (NDGD) of diffusion tensor imaging (DTI) on dispersion degree of fractional anisotropy (FA) values and its signal noise ratio (SNR) for adult brain tissues. Eight health volunteers were imaged by a 1.5T magnetic resonance scanner with different NDGD (6, 9, 12, 15, 20, 25, and 30 noncollinear) respectively, and seven FA maps associated with the different NDGD were obtained. Four region of interest (ROI) (genu and splenial of corpus callosum, genu and posterior limb of internal capsule) were chose in white matter of FA maps, and FA values and its SNR of the ROIs were computed and compared. Analysis of variance and independent-samples t-test were performed with a p value less than 0.05 regarded as statistical significance. Variance of FA values within the ROIs with stronger signals (genu and splenial of corpus callosum) fluctuated randomly and had no linear relationship with NDGD, and SNR increased slightly with NDGD increasing. But variance of FA values within the ROIs with weaker signals (genu and posterior limb of internal capsule) diminished significantly with NDGD increasing from 6 to 20, and slowly in the range from 20 to 30. SNR of FA values within the ROIs with weaker signals was improved significantly with NDGD increasing from 6 to 20 (P<0.05), and had no significant change while NDGD increasing from 20 to 30 (P>0.05). To detect FA values and its fluctuation and SNR of the ROIs with stronger signals, NDGD = 6 is enough, for detecting those of the ROIs with weaker signals, however, considering that reducing of scanning time to lower possibility of movementderived artifact and increasing of NDGD to improve precision of FA values, NDGD=20 is an optimal choice.
收录类别EI
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/3003]  
专题深圳先进技术研究院_医工所
作者单位2010
推荐引用方式
GB/T 7714
Zhang, Na,Deng, Zhensheng,Yin, Xiaojuan,et al. Effect of different number of diffusion gradient directions on dispersion degree of FA values and its SNR[C]. 见:4th International Conference on Bioinformatics and Biomedical Engineering, iCBBE 2010. Chengdu, China.

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。