A new technique to implement ultra-low frequency analog filters for electrophysiological signal acquisitions
文献类型:会议论文
作者 | Haixi Li; Jinyong Zhang; Lei Wang |
出版日期 | 2012 |
会议名称 | 9th International Workshop on Wearable and Implantable Body Sensor Networks, BSN 2012 |
会议地点 | London, United kingdom |
英文摘要 | This paper describes a new method to implement ultra-low frequency analog filters for electrophysiological signal acquisitions. Unlike the traditional pseudo-resistor or trans conductor-capacitor architectures, the proposed continues time filters employed current steering integrators which help decrease the capacitor area and reducing the total harmonic distorting (THD) simultaneously. Three basic structures (high pass, notch and low pass filters) were designed by proposing this technique and were implemented by 0.18 μm CMOS technology. Measurement results showed that the-3 dB of the low pass and high pass filters were 220 Hz and 0.05 Hz and notch frequency center of notch filter 50 Hz. Besides, the three filters' THD were measured to be-76 dB, -76 dB and -80 dB which are the lowest values with the comparison with other state-of-the-arts. |
收录类别 | EI |
语种 | 英语 |
源URL | [http://ir.siat.ac.cn:8080/handle/172644/4102] ![]() |
专题 | 深圳先进技术研究院_医工所 |
作者单位 | 2012 |
推荐引用方式 GB/T 7714 | Haixi Li,Jinyong Zhang,Lei Wang. A new technique to implement ultra-low frequency analog filters for electrophysiological signal acquisitions[C]. 见:9th International Workshop on Wearable and Implantable Body Sensor Networks, BSN 2012. London, United kingdom. |