Investigation of the effect of tube voltage and imaging geometry on phase contrast imaging for a micro-CT system

文献类型:期刊论文

作者Jianbao Gui; Jing Zou; Junyan Rong; Zhanli Hu; Qiyang Zhang; Hairong Zheng; Dan Xia
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
出版日期2012
英文摘要Based upon a bench-top micro-CT system, propagation-based phase-contrast imaging has been investigated using insects and a thin plastic sheet. The system mainly includes a micro-focus source with focal spot size of 13-20 mu m and a cooled X-ray CCD detector with pixel size of 24 mu m. The edge-enhancement effect can be found clearly in the acquired images. With a 0.5 mm thickness plastic edge phantom, the effects of X-ray tube voltage and imaging geometry on the phase-contrast imaging were investigated, and quantitative index, edge-enhancement index (EEI), were also calculated. In our study, an interesting phenomenon was observed that the phase-contrast effect becomes more pronounced as the tube voltage increases from 20 kVp to 90 kVp. Further investigation indicates that smaller focal spot size resulting from the reduction of tube current at higher tube voltage, has caused the unexpected phenomenon. Inferred from our results, phase-contrast effect is insensitive to the tube voltage in the range of 20-90 kVp (widely used in medical diagnosis); however, it is sensitive to the focal spot size. In addition, for the investigation of the effect of imaging geometry, an optimal geometric magnification range of 2.5-4.5 is suggested to get a good phase-contrast imaging for a micro-CT system with source-to-detector distance of 720 mm.
收录类别SCI
原文出处http://ac.els-cdn.com/S016890021102002X/1-s2.0-S016890021102002X-main.pdf?_tid=3fc3a39e-07a4-11e5-a5eb-00000aacb360&acdnat=1433083953_152014b89484d384595fd4c0ad72febf
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/3946]  
专题深圳先进技术研究院_医工所
作者单位NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
推荐引用方式
GB/T 7714
Jianbao Gui,Jing Zou,Junyan Rong,et al. Investigation of the effect of tube voltage and imaging geometry on phase contrast imaging for a micro-CT system[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2012.
APA Jianbao Gui.,Jing Zou.,Junyan Rong.,Zhanli Hu.,Qiyang Zhang.,...&Dan Xia.(2012).Investigation of the effect of tube voltage and imaging geometry on phase contrast imaging for a micro-CT system.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT.
MLA Jianbao Gui,et al."Investigation of the effect of tube voltage and imaging geometry on phase contrast imaging for a micro-CT system".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2012).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。