5 mHz highpass filter with -80 dB total harmonic distortions
文献类型:期刊论文
作者 | Haixi Li; Jinyong Zhang; Lei Wang |
刊名 | ELECTRONICS LETTERS
![]() |
出版日期 | 2012 |
英文摘要 | A fully integrated 5 mHz highpass filter for electrophysiological signal acquisitions is described. Unlike the traditional Gm-C or pseudo-resistor architectures, the proposed continuous-time filter employs the current steering technique, which helps decrease the capacitance area and reduce the total harmonic distortion (THD) simultaneously. This design was fabricated in 0.18 mu m CMOS technology. Experimental results indicate that it achieves -3 dB frequency band at 5 mHz, power consumption of 15 mu W and input referred noise of 3.8 mu V-rms. The -80 dB THD was measured at 1 Hz 0.2 V-p p sine wave input. |
收录类别 | SCI |
原文出处 | http://digital-library.theiet.org/content/journals/10.1049/el.2012.0132 |
语种 | 英语 |
源URL | [http://ir.siat.ac.cn:8080/handle/172644/3993] ![]() |
专题 | 深圳先进技术研究院_医工所 |
作者单位 | ELECTRONICS LETTERS |
推荐引用方式 GB/T 7714 | Haixi Li,Jinyong Zhang,Lei Wang. 5 mHz highpass filter with -80 dB total harmonic distortions[J]. ELECTRONICS LETTERS,2012. |