中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity

文献类型:期刊论文

作者Phillip Zhe Sun; Jie Lu; Yin Wu; Gang Xiao; Renhua Wu
刊名PHYSICS IN MEDICINE AND BIOLOGY
出版日期2013
英文摘要Chemical exchange saturation transfer (CEST) is a magnetic resonance imaging (MRI) contrast mechanism that can detect dilute CEST agents and microenvironmental properties, with a host of promising applications. Experimental measurement of the CEST effect is complex, and depends on not only CEST agent concentration and exchange rate, but also experimental parameters such as RF irradiation amplitude and scheme. Although echo planar imaging (EPI) has been increasingly used for CEST MRI, the relationship between CEST effect and repetition time (TR), RF irradiation duty cycle (DC) and EPI flip angle (alpha) has not been fully evaluated and optimized to enhance CEST MRI sensitivity. In addition, our study evaluated gradient echo CEST-EPI by quantifying the CEST effect and its signal-to-noise ratio per unit time (SNRput) as functions of TR, DC and alpha. We found that CEST effect increased with TR and DC but decreased with alpha. Importantly, we found that SNRput peaked at intermediate TRs of about twice the T-1 and alpha, at approximately 75 degrees, and increased with RF DC. The simulation results were validated using a dual-pH creatine-gel CEST phantom. In summary, our study provides a useful framework for optimizing CEST MRI experiments.
收录类别SCI
原文出处http://iopscience.iop.org/0031-9155/58/17/N229
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/4767]  
专题深圳先进技术研究院_医工所
作者单位PHYSICS IN MEDICINE AND BIOLOGY
推荐引用方式
GB/T 7714
Phillip Zhe Sun,Jie Lu,Yin Wu,et al. Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity[J]. PHYSICS IN MEDICINE AND BIOLOGY,2013.
APA Phillip Zhe Sun,Jie Lu,Yin Wu,Gang Xiao,&Renhua Wu.(2013).Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity.PHYSICS IN MEDICINE AND BIOLOGY.
MLA Phillip Zhe Sun,et al."Evaluation of the dependence of CEST-EPI measurement on repetition time, RF irradiation duty cycle and imaging flip angle for enhanced pH sensitivity".PHYSICS IN MEDICINE AND BIOLOGY (2013).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。