Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods

文献类型:期刊论文

作者Pan Han; Ye Chen; Lijuan Ao; Gaosheng Xie; Huihui Li; Lei Wang; Yongjin Zhou
刊名BIOMEDICAL ENGINEERING ONLINE
出版日期2013
英文摘要Background: Ultrasonography is a convenient technique to investigate muscle properties and has been widely used to look into muscle functions since it is non-invasive and real-time. Muscle thickness, a quantification which can effectively reflect the muscle activities during muscle contraction, is an important measure for musculoskeletal studies using ultrasonography. The traditional manual operation to read muscle thickness is subjective and time-consuming, therefore a number of studies have focused on the automatic estimation of muscle fascicle orientation and muscle thickness, to which the speckle noises in ultrasound images could be the major obstacle. There have been two popular methods proposed to enhance the hyperechoic regions over the speckles in ultrasonography, namely Gabor Filtering and Multiscale Vessel Enhancement Filtering (MVEF). Methods: A study on gastrocnemius muscle is conducted to quantitatively evaluate whether and how these two methods could help the automatic estimation of the muscle thickness based on Revoting Hough Transform (RVHT). The muscle thickness results obtained from each of the two methods are compared with the results from manual measurement, respectively. Data from an aged subject with cerebral infarction is also studied. Results: It's shown in the experiments that, Gabor Filtering and MVEF can both enable RVHT to generate comparable results of muscle thickness to those by manual drawing (mean +/- SD, 1.45 +/- 0.48 and 1.38 +/- 0.56 mm respectively). However, the MVEF method requires much less computation than Gabor Filtering. Conclusions: Both methods, as preprocessing procedure can enable RVHT the automatic estimation of muscle thickness and MVEF is believed to be a better choice for real-time applications.
收录类别SCI
原文出处http://www.biomedcentral.com/content/pdf/1475-925X-12-6.pdf
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/4866]  
专题深圳先进技术研究院_医工所
作者单位BIOMEDICAL ENGINEERING ONLINE
推荐引用方式
GB/T 7714
Pan Han,Ye Chen,Lijuan Ao,et al. Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods[J]. BIOMEDICAL ENGINEERING ONLINE,2013.
APA Pan Han.,Ye Chen.,Lijuan Ao.,Gaosheng Xie.,Huihui Li.,...&Yongjin Zhou.(2013).Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods.BIOMEDICAL ENGINEERING ONLINE.
MLA Pan Han,et al."Automatic thickness estimation for skeletal muscle in ultrasonography: evaluation of two enhancement methods".BIOMEDICAL ENGINEERING ONLINE (2013).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。