中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions

文献类型:期刊论文

作者Xue Zhang; Yang Xiao; Jie Zeng; Weibao Qiu; Ming Qian; Congzhi Wang; Rongqin Zheng; Hairong Zheng
刊名EUROPEAN JOURNAL OF RADIOLOGY
出版日期2014
英文摘要Purpose: To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Materials and methods: Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Results: Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (A(z) value) for the proposed method was higher than the A(z) value for visual assessment (0.96 vs. 0.93). Conclusion: Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy.
收录类别SCI
原文出处http://www.sciencedirect.com/science/article/pii/S0720048X1300507X
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/5756]  
专题深圳先进技术研究院_医工所
作者单位EUROPEAN JOURNAL OF RADIOLOGY
推荐引用方式
GB/T 7714
Xue Zhang,Yang Xiao,Jie Zeng,et al. Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions[J]. EUROPEAN JOURNAL OF RADIOLOGY,2014.
APA Xue Zhang.,Yang Xiao.,Jie Zeng.,Weibao Qiu.,Ming Qian.,...&Hairong Zheng.(2014).Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions.EUROPEAN JOURNAL OF RADIOLOGY.
MLA Xue Zhang,et al."Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions".EUROPEAN JOURNAL OF RADIOLOGY (2014).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。