中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY

文献类型:期刊论文

作者Wang Yongjian; Pu Lina; Wu Dan; Lin WanHua; Wong Kelvin Kian Loong; Zhang Heye
刊名JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY
出版日期2015
英文摘要The monitoring of arterial oxygen saturation (SaO(2)) is a common practice in both clinical and home environments, and the process of monitoring can be exercised invasively or non-invasively. In the past decades, the pulse oximeter is one of the most popular non-invasive devices that use photoplethysmography (PPG) to measure SaO(2). As the pulse oximeter requires calibration prior to application in clinical practice, a significant number of calibration methods have been proposed based on experimental data collected from human volunteers. Alternatively, models may be derived from the Lambert-Beer law or the photon diffusion equation (PDE). However, most of such calibrated oximeter can only provide accurate readings of SaO(2) at high versus the low levels. We propose to apply an extra-boundary condition to solve the PDE, and then to develop a model-based calibration method that relate optical measurements to the level of SaO(2) in this work. Then, we validate our method against previous model-based methods and an oximeter simulator with higher accuracy when the level of SaO(2) is greater than 90%. In practice, our model-based method can still maintain a good performance when the level of SaO(2) decreases to 60%, thereby demonstrating high potential in the accurate evaluation of the oxygen level of patients by PPG.
收录类别SCI
原文出处http://www.worldscientific.com/doi/abs/10.1142/S0219519415500153
语种英语
源URL[http://ir.siat.ac.cn:8080/handle/172644/7048]  
专题深圳先进技术研究院_医工所
作者单位JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY
推荐引用方式
GB/T 7714
Wang Yongjian,Pu Lina,Wu Dan,et al. AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY[J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY,2015.
APA Wang Yongjian,Pu Lina,Wu Dan,Lin WanHua,Wong Kelvin Kian Loong,&Zhang Heye.(2015).AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY.JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY.
MLA Wang Yongjian,et al."AN ACCURATE CALIBRATION METHOD FOR THE MEASUREMENT OF ARTERIAL OXYGEN SATURATION USING PHOTOPLETHYSMOGRAPHY".JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY (2015).

入库方式: OAI收割

来源:深圳先进技术研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。