An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T
文献类型:期刊论文
作者 | Xiaoqing Hu; Lei Zhang; Xiaoliang Zhang; Huabin Zhu; Xiao Chen; Yongqin Zhang; Yiu-Cho Chung; Xin Liu; Hairong Zheng; Ye Li |
刊名 | MEDICAL PHYSICS
![]() |
出版日期 | 2016 |
英文摘要 | Purpose: Carotid artery diseases due to plaque buildup at the carotid bifurcation are a leading cause of stroke. Accurate plaque quantification and characterization of plaque composition and morphology by magnetic resonance imaging (MRI) is essential to identifying high-risk patients. Difficulties in detecting plaque, which is physically small, and the unique physiological structure of the carotid artery make use of a radio frequency (RF) coil array with high resolution, large longitudinal coverage, and deep penetration idealfor clinical examinations. The goal of this project was to design and fabricate a sensitive RF coil array with sufficient imaging coverage and signal-to-noise ratio (SNR) for carotid artery imaging at 3 T. Methods: Based on clinical requirements and the anatomical structure of the human carotid artery, an 8-channel carotid coil array was designed and fabricated for 3 T MRI of the carotid artery in humans. The performance of the proposed 8-channel carotid coil array was validated through bench tests and MR imaging experiments on a 3 T whole body MRI scanner. Its performance was also compared experimentally to the performance of a commercial 4-channel phased array carotid coil designed by Machnet BV (Machnet BV coil, Roden, Netherlands). Results: The 8-channel carotid coil array performed significantly better in imaging the carotid artery than the commercial 4-channel Machnet BV coil in terms of the SNR, coverage, and penetration depth. In parallel imaging, the proposed 8-channel carotid coil array demonstrated a much lower maximum value and average value of the geometry factor in the region of interest. Carotid artery images acquired in vivo using the proposed 8-channel carotid artery coil and the commercial 4-channel Machnet BV coil were also compared, demonstrating the former's potential for clinical diagnosis. Conclusions: Based on the analyses of phantom and in vivo imaging studies, the proposed 8-channel carotid coil array has the potential for use in clinical diagnosis, performing better in terms of SNR, imaging coverage, and penetration depth than the commercial 4-channel carotid artery coil array at 3 T. In future studies, the proposed 8-channel carotid coil array can also serve as an important part of a large-scale multichannel coil array for imaging the whole carotid artery system, including the extracranial and intracranial arteries. |
收录类别 | SCI |
原文出处 | http://scitation.aip.org/content/aapm/journal/medphys/43/4/10.1118/1.4944500 |
语种 | 英语 |
源URL | [http://ir.siat.ac.cn:8080/handle/172644/10450] ![]() |
专题 | 深圳先进技术研究院_医工所 |
作者单位 | MEDICAL PHYSICS |
推荐引用方式 GB/T 7714 | Xiaoqing Hu,Lei Zhang,Xiaoliang Zhang,et al. An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T[J]. MEDICAL PHYSICS,2016. |
APA | Xiaoqing Hu.,Lei Zhang.,Xiaoliang Zhang.,Huabin Zhu.,Xiao Chen.,...&Ye Li.(2016).An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T.MEDICAL PHYSICS. |
MLA | Xiaoqing Hu,et al."An 8-channel RF coil array for carotid artery MR imaging in humans at 3 T".MEDICAL PHYSICS (2016). |
入库方式: OAI收割
来源:深圳先进技术研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。