英文摘要A new micro embedded telemetry system was developed for the amperometric sensing detection. Its output voltage range was +/- 0. 5 V and resolution was < 1 mV. The current acquisition range was +/- 1 mu A and the minimum resolution was 0. 2 nA. This telemetry system was designed based on microprocessor ADuCM360, including a potentiostat, a current detection module and a radio module. And the size was only 24 mm. 13 mm. 11 mm. The computer software written in LabVIEW language was used for data storage and display. In order to verify the accuracy and reliability of this system, an electrical performance test was performed. The current response for ascorbic acid with different concentration was recorded by using the telemetry system. The potential of working electrode was set as 30 mV, and the current response of ascorbic acid electrode had a good linear relationship with its concentration within the concentration range of 50-300 mu mol/L. Linear equation was I(nA) = 2. 98C(AA) (mu mol/L) - 137. 39, and linear correlation coefficient R-2 = 0. 984. Moreover, the applicability of the instrument in the study for living animals was explored by using the cerebral ischemia as model.
收录类别SCI
语种英语
源URL[http://ir.iccas.ac.cn/handle/121111/36436]  
专题化学研究所_活体分析化学实验室
作者单位1.Beihang Univ, Sch Reliabil & Syst Engn, Beijing 100191, Peoples R China
2.Chinese Acad Sci, Inst Chem, Key Lab Analyt Chem Living Biosyst, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Li Xiao-Gang,Guo Bin-Qian,Qin Tai-Chun,et al. Design and Implementation of Embedded Telemetry System for Amperometric Detection[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2016,44(9):1465-1470.
APA Li Xiao-Gang,Guo Bin-Qian,Qin Tai-Chun,Hao Jie,Yu Ping,&Mao Lan-Qun.(2016).Design and Implementation of Embedded Telemetry System for Amperometric Detection.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,44(9),1465-1470.
MLA Li Xiao-Gang,et al."Design and Implementation of Embedded Telemetry System for Amperometric Detection".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 44.9(2016):1465-1470.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。