Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons
文献类型:期刊论文
作者 | Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong |
刊名 | JOURNAL OF CHROMATOGRAPHY A
![]() |
出版日期 | 2016-01-04 |
卷号 | 1427页码:134-141 |
关键词 | GC-FID NMHCs Capillary column The ambient air |
英文摘要 | A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 degrees C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (0V-1,30 m x 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 similar to 170 degrees C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R-2=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city. (C) 2015 Elsevier B.V. All rights reserved. |
源URL | [http://ir.rcees.ac.cn/handle/311016/35704] ![]() |
专题 | 生态环境研究中心_大气环境科学实验室 |
推荐引用方式 GB/T 7714 | Liu, Chengtang,Mu, Yujing,Zhang, Chenglong,et al. Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons[J]. JOURNAL OF CHROMATOGRAPHY A,2016,1427:134-141. |
APA | Liu, Chengtang.,Mu, Yujing.,Zhang, Chenglong.,Zhang, Zhibo.,Zhang, Yuanyuan.,...&Quan, Jiannong.(2016).Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons.JOURNAL OF CHROMATOGRAPHY A,1427,134-141. |
MLA | Liu, Chengtang,et al."Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons".JOURNAL OF CHROMATOGRAPHY A 1427(2016):134-141. |
入库方式: OAI收割
来源:生态环境研究中心
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。