中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Portable detection of clenbuterol using a smartphone-based electrochemical biosensor with electric field-driven acceleration

文献类型:期刊论文

作者Dou, YZ; Jiang, ZN; Deng, WP; Su, J; Chen, SX; Song, HY; Aldalbahi, A; Zuo, XL; Song, SP; Shi, JY
刊名JOURNAL OF ELECTROANALYTICAL CHEMISTRY
出版日期2016
卷号781页码:339-344
关键词Electrochemistry Portable Sensor Smartphone Electrical field
ISSN号1572-6657
通讯作者Song, SP ; Fan, CH (reprint author), Chinese Acad Sci, Shanghai Inst Appl Phys, Div Phys Biol, Shanghai 201800, Peoples R China. ; Song, SP ; Fan, CH (reprint author), Chinese Acad Sci, Shanghai Inst Appl Phys, Bioimaging Ctr, Shanghai Synchrotron Radiat Facil, Shanghai 201800, Peoples R China.
英文摘要We have developed a fast, highly sensitive and low-cost biosensing system for the detection of clenbuterol (CLB), using a homemade mobile electrochemical device with an electric field-driven acceleration strategy. This system consists of an embedded circuit in smartphone for signal processing and a screen-printed carbon electrode (SPCE) modified with multi-walled carbon nanotubes (MWNTs) and goat anti mouse-immunoglobulin G (IgG) sensing layer (MWNTs-I-layer). CLB monoclonal antibody was assembled through its binding to the surface confined antibody. Such modified electrodes were used for rapid and sensitive amperometric immunosensing detection of CLB. Horseradish peroxidase-coupled CLB (CLB-HRP) competed with free CLB in the samples to bind the monoclonal antibody. By using this mobile system, we could detect CLB ranging from 03 ng.mL(-1) to 100 ng.mL(-1) with the detection limit of 0.076 ng.mL(-1). The whole competitive-type detection process was finished within 6 min. We expect this device can meet the requirements for field detection of various food security-related species. (C) 2016 Elsevier B.V. All rights reserved.
收录类别SCI
语种英语
WOS记录号WOS:000390494200052
源URL[http://ir.sinap.ac.cn/handle/331007/26599]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Dou, YZ,Jiang, ZN,Deng, WP,et al. Portable detection of clenbuterol using a smartphone-based electrochemical biosensor with electric field-driven acceleration[J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY,2016,781:339-344.
APA Dou, YZ.,Jiang, ZN.,Deng, WP.,Su, J.,Chen, SX.,...&Fan, CH.(2016).Portable detection of clenbuterol using a smartphone-based electrochemical biosensor with electric field-driven acceleration.JOURNAL OF ELECTROANALYTICAL CHEMISTRY,781,339-344.
MLA Dou, YZ,et al."Portable detection of clenbuterol using a smartphone-based electrochemical biosensor with electric field-driven acceleration".JOURNAL OF ELECTROANALYTICAL CHEMISTRY 781(2016):339-344.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。