中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution

文献类型:期刊论文

作者Li, N; Li, XH; Wang, YZ; Liu, GF; Zhou, P; Wu, HJ; Hong, CX; Bian, FG; Zhang, RG
刊名JOURNAL OF APPLIED CRYSTALLOGRAPHY
出版日期2016
卷号49页码:1428-1432
关键词biological small-angle X-ray scattering automation and high brilliance structural biology
ISSN号1600-5767
通讯作者Zhang, RG (reprint author), Shanghai Inst Biol Sci, Natl Ctr Prot Sci Shanghai, 320 Yueyang Rd, Shanghai 200031, Peoples R China. ; Bian, FG (reprint author), Shanghai Inst Appl Phys, Shanghai Synchrotron Radiat Facil, 239 Zhangheng Rd, Shanghai 201204, Peoples R China.
英文摘要The beamline BL19U2 is located in the Shanghai Synchrotron Radiation Facility (SSRF) and is its first beamline dedicated to biological material small-angle X-ray scattering (BioSAXS). The electrons come from an undulator which can provide high brilliance for the BL19U2 end stations. A double flat silicon crystal (111) monochromator is used in BL19U2, with a tunable monochromatic photon energy ranging from 7 to 15 keV. To meet the rapidly growing demands of crystallographers, biochemists and structural biologists, the BioSAXS beamline allows manual and automatic sample loading/unloading. A Pilatus 1M detector (Dectris) is employed for data collection, characterized by a high dynamic range and a short readout time. The highly automated data processing pipeline SASFLOW was integrated into BL19U2, with help from the BioSAXS group of the European Molecular Biology Laboratory (EMBL, Hamburg), which provides a user-friendly interface for data processing. The BL19U2 beamline was officially opened to users in March 2015. To date, feedback from users has been positive and the number of experimental proposals at BL19U2 is increasing. A description of the new BioSAXS beamline and the setup characteristics is given, together with examples of data obtained.
收录类别SCI
语种英语
WOS记录号WOS:000388354800005
源URL[http://ir.sinap.ac.cn/handle/331007/26656]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Li, N,Li, XH,Wang, YZ,et al. The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution[J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY,2016,49:1428-1432.
APA Li, N.,Li, XH.,Wang, YZ.,Liu, GF.,Zhou, P.,...&Zhang, RG.(2016).The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution.JOURNAL OF APPLIED CRYSTALLOGRAPHY,49,1428-1432.
MLA Li, N,et al."The new NCPSS BL19U2 beamline at the SSRF for small-angle X-ray scattering from biological macromolecules in solution".JOURNAL OF APPLIED CRYSTALLOGRAPHY 49(2016):1428-1432.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。