Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS
文献类型:期刊论文
作者 | Gao, Hailiang1; Gu, Xingfa1; Yu, Tao1; Sun, Yuan1; Liu, Qiyue1 |
刊名 | IEEE Transactions on Geoscience and Remote Sensing |
出版日期 | 2016 |
卷号 | 54期号:8页码:4847-4854 |
关键词 | MICROWAVE-FREQUENCIES DIELECTRIC-PROPERTIES COMPLEX PERMITTIVITY VEGETATION |
英文摘要 | The panchromatic and multispectral (PMS) sensor is a high spatial resolution sensor aboard the GF-1 satellite launched on April 26, 2013. This paper focuses on the cross-calibration of the PMS sensor using Terra/Moderate-Resolution Imaging Spectroradiometer (MODIS) and Landsat 8/Operational Land Imager (OLI). Two matched-image adjustment factors (MIAFs) are used in the cross-calibration which are the radiance MIAF and reflectance MIAF. Two test sites are chosen as the regions of interest. One is the Dunhuang test site, which has been used for the vicarious calibration of Chinese satellites since later 1990s. The other is the Golmud test site, which is a new site with no ground measured data available. The results show that both the Dunhuang and Golmud test sites can be used for cross-calibration. This paper reveals that the cross-calibration of the PMS sensor using OLI is better than using MODIS, as the calibration coefficient difference between the two test sites with OLI is smaller than that with MODIS. The uncertainty analysis results show that the uncertainty of cross-calibration using OLI is 5%-7% when the ground data are not available. © 2016 IEEE. |
学科主题 | Geochemistry & Geophysics; Engineering; Remote Sensing; Imaging Science & Photographic Technology |
类目[WOS] | Geochemistry & Geophysics ; Engineering, Electrical & Electronic ; Remote Sensing ; Imaging Science & Photographic Technology |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:20161802335998 |
源URL | [http://ir.radi.ac.cn/handle/183411/39183] |
专题 | 遥感与数字地球研究所_SCI/EI期刊论文_期刊论文 |
作者单位 | 1. Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing 2.100101, China |
推荐引用方式 GB/T 7714 | Gao, Hailiang,Gu, Xingfa,Yu, Tao,et al. Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS[J]. IEEE Transactions on Geoscience and Remote Sensing,2016,54(8):4847-4854. |
APA | Gao, Hailiang,Gu, Xingfa,Yu, Tao,Sun, Yuan,&Liu, Qiyue.(2016).Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS.IEEE Transactions on Geoscience and Remote Sensing,54(8),4847-4854. |
MLA | Gao, Hailiang,et al."Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS".IEEE Transactions on Geoscience and Remote Sensing 54.8(2016):4847-4854. |
入库方式: OAI收割
来源:遥感与数字地球研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。