中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS

文献类型:期刊论文

作者Gao, Hailiang1; Gu, Xingfa1; Yu, Tao1; Sun, Yuan1; Liu, Qiyue1
刊名IEEE Transactions on Geoscience and Remote Sensing
出版日期2016
卷号54期号:8页码:4847-4854
关键词MICROWAVE-FREQUENCIES DIELECTRIC-PROPERTIES COMPLEX PERMITTIVITY VEGETATION
英文摘要The panchromatic and multispectral (PMS) sensor is a high spatial resolution sensor aboard the GF-1 satellite launched on April 26, 2013. This paper focuses on the cross-calibration of the PMS sensor using Terra/Moderate-Resolution Imaging Spectroradiometer (MODIS) and Landsat 8/Operational Land Imager (OLI). Two matched-image adjustment factors (MIAFs) are used in the cross-calibration which are the radiance MIAF and reflectance MIAF. Two test sites are chosen as the regions of interest. One is the Dunhuang test site, which has been used for the vicarious calibration of Chinese satellites since later 1990s. The other is the Golmud test site, which is a new site with no ground measured data available. The results show that both the Dunhuang and Golmud test sites can be used for cross-calibration. This paper reveals that the cross-calibration of the PMS sensor using OLI is better than using MODIS, as the calibration coefficient difference between the two test sites with OLI is smaller than that with MODIS. The uncertainty analysis results show that the uncertainty of cross-calibration using OLI is 5%-7% when the ground data are not available. © 2016 IEEE.
学科主题Geochemistry & Geophysics; Engineering; Remote Sensing; Imaging Science & Photographic Technology
类目[WOS]Geochemistry & Geophysics ; Engineering, Electrical & Electronic ; Remote Sensing ; Imaging Science & Photographic Technology
收录类别SCI ; EI
语种英语
WOS记录号WOS:20161802335998
源URL[http://ir.radi.ac.cn/handle/183411/39183]  
专题遥感与数字地球研究所_SCI/EI期刊论文_期刊论文
作者单位1. Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing
2.100101, China
推荐引用方式
GB/T 7714
Gao, Hailiang,Gu, Xingfa,Yu, Tao,et al. Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS[J]. IEEE Transactions on Geoscience and Remote Sensing,2016,54(8):4847-4854.
APA Gao, Hailiang,Gu, Xingfa,Yu, Tao,Sun, Yuan,&Liu, Qiyue.(2016).Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS.IEEE Transactions on Geoscience and Remote Sensing,54(8),4847-4854.
MLA Gao, Hailiang,et al."Cross-Calibration of GF-1 PMS Sensor with Landsat 8 OLI and Terra MODIS".IEEE Transactions on Geoscience and Remote Sensing 54.8(2016):4847-4854.

入库方式: OAI收割

来源:遥感与数字地球研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。