中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Validation of the calibration coefficient of the GaoFen-1 PMS sensor using the landsat 8 OLI

文献类型:期刊论文

作者Gao, Hailiang1; Gu, Xingfa1; Yu, Tao1; Liu, Li1; Sun, Yuan1; Xie, Yong1; Liu, Qiyue1
刊名Remote Sensing
出版日期2016
卷号8期号:2
关键词REMOTE-SENSING MEASUREMENTS RADIANCE MEASUREMENTS PRODUCTS LAND FRACTION NETWORK AERONET REGION
通讯作者Gu, Xingfa (guxingfa@radi.ac.cn)
英文摘要The panchromatic and multispectral (PMS) sensor is an optical imaging sensor aboard the Gao Fen-1 (GF-1) satellite. This work describes an approach to validate the calibration coefficients of the PMS sensors based on the image data of the Landsat 8 Operational Land Imager (OLI). Two image pairs, one obtained over the Dunhuang test site and the other over the Golmud test site, were used in this paper. Two spectral band adjustment factors (SBAF), given as the radiance SBAF and reflectance SBAF, were applied to correct the differences in the respective images caused by the relative spectral responses of the PMS sensor and OLI. Uncertainties in the SBAF values arising from atmospheric parameters and the absence of a measured ground spectrum were analyzed in this paper. The results show that the average relative differences of top-of-atmosphere radiance and reflectance values for each band between the PMS sensor and OLI images are 2%-5% for most bands, after SBAF correction with a measured ground spectrum or fitted spectrum. It is demonstrated that the OLI image can be used to validate the calibration coefficient of the PMS sensor, even if the image pairs are not imaged on the same day. © 2016 by the authors.
学科主题Remote Sensing
类目[WOS]Remote Sensing
收录类别SCI ; EI
语种英语
WOS记录号WOS:20161302145787
源URL[http://ir.radi.ac.cn/handle/183411/39245]  
专题遥感与数字地球研究所_SCI/EI期刊论文_期刊论文
作者单位1. State Key Laboratory of Remote Sensing Science, Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing, China
2. China Centre for Resources Satellite Data and Application, Beijing, China
推荐引用方式
GB/T 7714
Gao, Hailiang,Gu, Xingfa,Yu, Tao,et al. Validation of the calibration coefficient of the GaoFen-1 PMS sensor using the landsat 8 OLI[J]. Remote Sensing,2016,8(2).
APA Gao, Hailiang.,Gu, Xingfa.,Yu, Tao.,Liu, Li.,Sun, Yuan.,...&Liu, Qiyue.(2016).Validation of the calibration coefficient of the GaoFen-1 PMS sensor using the landsat 8 OLI.Remote Sensing,8(2).
MLA Gao, Hailiang,et al."Validation of the calibration coefficient of the GaoFen-1 PMS sensor using the landsat 8 OLI".Remote Sensing 8.2(2016).

入库方式: OAI收割

来源:遥感与数字地球研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。