Calibration and analysis of HJ-IB/IRS thermal infrared channel based on the historical data
文献类型:期刊论文
作者 | Yang, Hongyan1; Li, Jiaguo1; Zhu, Li1; Yin, Yaqiu1; Zhang, Yonghong1; Lei, Qiuliang1; Chen, Yijin1 |
刊名 | Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
![]() |
出版日期 | 2016 |
卷号 | 45期号:3 |
英文摘要 | To obtain the absolute radiation calibration coefficient of IRS B08 in 2013, TERRA/MODIS was used as the reference sensor, Qinghai lake was taken as the research object, twin-channel difference model was applied to cross-calibration. By comparing the influence of different observation angles and different of imaging receiving time on calibration precision, it can be concluded that the best cross-calibration condition is the observation angle within 30° and the difference of imaging receiving time about 1 hour. Under this condition, calibration accuracy of regression fitting is the highest. According to the precision verification using satellite-ground synchronous experiment data around Ningde area on 26, October, 2013, result shows that error of apparent radiance and brightness temperature is within 0.02 Wm-2μm-1sr-1and 0.15 respectively. Besides, compared with the historical calibration coefficients from 2008 to 2010, the new calibration coefficients of 2013 increased by 98.50%, 98.24%, 90.21%, 20.87% and 98.31% respectively. Overall, the obtained calibration coefficient has a high accuracy, that can be used to the IRS B08. © 2016, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved. |
收录类别 | EI |
语种 | 中文 |
WOS记录号 | WOS:20161802339214 |
源URL | [http://ir.radi.ac.cn/handle/183411/39627] ![]() |
专题 | 遥感与数字地球研究所_SCI/EI期刊论文_期刊论文 |
作者单位 | 1. Institute of Remote Sensing and Digital Earth, Chinese Academy of Sciences, Beijing, China 2. Satellite Environment Center, Ministry of Environmental Protection, Beijing, China 3. Institute of Agricultural Resources and Regional Planning, CAAS, Beijing, China 4. China University of Mining & Technology (Beijing), Beijing, China |
推荐引用方式 GB/T 7714 | Yang, Hongyan,Li, Jiaguo,Zhu, Li,et al. Calibration and analysis of HJ-IB/IRS thermal infrared channel based on the historical data[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2016,45(3). |
APA | Yang, Hongyan.,Li, Jiaguo.,Zhu, Li.,Yin, Yaqiu.,Zhang, Yonghong.,...&Chen, Yijin.(2016).Calibration and analysis of HJ-IB/IRS thermal infrared channel based on the historical data.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,45(3). |
MLA | Yang, Hongyan,et al."Calibration and analysis of HJ-IB/IRS thermal infrared channel based on the historical data".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 45.3(2016). |
入库方式: OAI收割
来源:遥感与数字地球研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。