Effects of Acoustic Barriers and Crosswind on the Operating Performance of Evaporative Cooling Tower Groups
文献类型:期刊论文
作者 | Dang, C., Jia, L. and Yang, L. X.1 |
出版日期 | 2016 |
关键词 | evaporative cooling tower groups acoustic barriers crosswind reflux flow operating performance air-cooled condensers mass-transfer counter-flow |
中文摘要 | Most evaporative cooling towers are arranged on building roof due to the limitation of space and noise, and acoustic barriers are always installed around cooling towers in practical applications. The existence of acoustic bathers and crosswind may affect the recirculation phenomenon which is directly related to the operating performance of cooling towers. In this study, a physical and mathematical computation model is proposed to research the crosswind and distance between acoustic bathers and inlet of cooling towers. Both sensible and latent heat are considered in this research. The reflux flow rate and performance ratio are obtained to evaluate the recirculation and operating performance, respectively. The results show that the higher the crosswind velocity, the larger the reflux flow rate, and the lower the performance ratio of cooling tower groups. For high crosswind velocity, the presence of acoustic barriers is useful to inhibit reflux and improve operating performance, especially for ICE cooling tower groups. In addition, the optimum values are recommended for LiBr/ICE cooling tower groups in the research cases The variation of reflux flow rate and performance ratio with the acoustic bathers' distance presents a parabolic tendency. |
源URL | [http://ir.etp.ac.cn/handle/311046/113042] ![]() |
专题 | 工程热物理研究所_Journal of Thermal Science_期刊论文 |
作者单位 | 1.[Dang Chao 2.Jia Li 3.Yang Lixin] Beijing Jiaotong Univ, Inst Thermal Engn, Sch Mech Elect & Control Engn, Beijing 100044, Peoples R China. [Dang Chao 4.Jia Li 5.Yang Lixin] Beijing Key Lab Flow & Heat Transfer Phase Changi, Beijing 100044, Peoples R China. |
推荐引用方式 GB/T 7714 | Dang, C., Jia, L. and Yang, L. X.. Effects of Acoustic Barriers and Crosswind on the Operating Performance of Evaporative Cooling Tower Groups[J],2016. |
APA | Dang, C., Jia, L. and Yang, L. X..(2016).Effects of Acoustic Barriers and Crosswind on the Operating Performance of Evaporative Cooling Tower Groups.. |
MLA | Dang, C., Jia, L. and Yang, L. X.."Effects of Acoustic Barriers and Crosswind on the Operating Performance of Evaporative Cooling Tower Groups".(2016). |
入库方式: OAI收割
来源:工程热物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。