中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of neurotransmitters in rat telencephalon using pre-column fluorescence derivatization with high performance liquid chromatography/mass spectrometry

文献类型:期刊论文

作者Zhao Xian-En1,2; Suo You-Rui1
刊名chinese journal of analytical chemistry
出版日期2008
卷号36期号:1页码:12-18
关键词rat telencephalon neurotransmitter exercise pre-column derivatization high performance liquid chromatography-mass spectrometry fluorescence detection
英文摘要a sensitive method has been developed for the simultaneous determination of 5 neurotransmitters glutamic acid, gamma-amino-butyric acid, dopamine, 5-hydroxytryptamine, 5-hydroxyindole acetic acid) with i, 2-benzo-3, 4-dihydrocarbazole-9-ethyl chloroformate (bceoc) as derivatization reagent on a reversed-phase hypersil bds c-18 column (100 mm x 4.6 mm, 5 mu m) with a gradient elution followed by high performance liquid chromatography (hplc) via fluorescence detection at 390 nm (excitation wavelength 333 nm) and online mass spectrometric identification. the linear range of 5 neurotransmitters was 24 fmol - 200 pmol, all the correlation coefficients were > 0.9997, the detection limit was 4.0 - 12.6 fmol (at a signal to noise ratio of 3: 1). the ms identification of 5 neurotransmitter derivatives was carried out by post-column online mass spectrometry with electrospray ion source, the ms/ms fragment ions of them were listed, and the ms/ms cleavage mode of representative 5-hydroxytryptamine derivative was analyzed. under all the above optimum experimental conditions, the contents of 5 neurotransmitters in telencephalon of 64 rat (classified as 2 groups, a group: quiet contrast group, b group: training group) at 4 states (a: quiet state, b: 1 h after exercise, c: at exercising exhaust, d: 12 h after exercising exhaust) were determined. it is indicated that a long period of time medium intensity training can effectively improve mice exercise capacity and obviously promote to restore central fatigue after resistance exercise. the established method exhibits high sensitivity and excellent reproducibility, and provides a new technology for the simultaneous determination of monoamine and amino acid neurotransmitters in rat telencephalon.
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, analytical
研究领域[WOS]chemistry
关键词[WOS]amino-acids ; monoamine neurotransmitters ; mass-spectrometry ; brain ; serum
收录类别SCI
语种英语
WOS记录号WOS:000254075300003
源URL[http://ir.nwipb.ac.cn/handle/363003/6871]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位1.Chinese Acad Sci, NW Inst Plateau Biol, Xining 810001, Peoples R China
2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Zhao Xian-En,Suo You-Rui. Determination of neurotransmitters in rat telencephalon using pre-column fluorescence derivatization with high performance liquid chromatography/mass spectrometry[J]. chinese journal of analytical chemistry,2008,36(1):12-18.
APA Zhao Xian-En,&Suo You-Rui.(2008).Determination of neurotransmitters in rat telencephalon using pre-column fluorescence derivatization with high performance liquid chromatography/mass spectrometry.chinese journal of analytical chemistry,36(1),12-18.
MLA Zhao Xian-En,et al."Determination of neurotransmitters in rat telencephalon using pre-column fluorescence derivatization with high performance liquid chromatography/mass spectrometry".chinese journal of analytical chemistry 36.1(2008):12-18.

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。