中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Improvements in the selectivity of electrochemical detectors for liquid chromatography and flow injection analysis using the self-assembled n-alkanethiol monolayer-modified au electrode

文献类型:期刊论文

作者Liu ZM ; Li JH ; Dong SJ ; Wang EK
刊名analytical chemistry
出版日期1996
卷号68期号:14页码:2432-2436
关键词ORGANIZED MOLECULAR ASSEMBLIES STRUCTURAL CHARACTERIZATION THIOL MONOLAYERS GOLD ELECTRODES STREAMS SURFACE FILM
ISSN号0003-2700
中文摘要4-aminophenol (4-ap), paracetamol (prct), norepinephrine (ne), and dopamine (da) (all somewhat hydrophobic compounds) were hplc electrochemically detected while the signals from uric acid (ua) and ascorbic acid (aa) (both hydrophilic compounds at the ph studied) were minimized, taking advantage of the permselectivity of the self-assembled n-alkanethiol monolayer (c-10-sam)-modified au electrodes based on solute polarity, the effects of various factors, such as the chain length of the n-alkanethiol modifier, modifying time, and ph value, on the permeability of c-10-sam coatings were examined, the calibration curves, linear response ranges, detection limits, and reproducibilities of the ec detector for 4-ap, prct, ne, and da were obtained, the result shows that the ec detector can be applied in the chromatographic detection of 4-ap, prct, ne, and da in urine, effectively removing the influence of ua and aa in high concentrations existing in biological samples. as a result, a great improvement in the selectivity of ec detectors has been achieved by using au electrodes coated with neutral n-alkanethiol monolayer.
收录类别SCI收录期刊论文
语种英语
公开日期2010-12-22 ; 2011-06-09
源URL[http://ir.ciac.jl.cn/handle/322003/25379]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Liu ZM,Li JH,Dong SJ,et al. Improvements in the selectivity of electrochemical detectors for liquid chromatography and flow injection analysis using the self-assembled n-alkanethiol monolayer-modified au electrode[J]. analytical chemistry,1996,68(14):2432-2436.
APA Liu ZM,Li JH,Dong SJ,&Wang EK.(1996).Improvements in the selectivity of electrochemical detectors for liquid chromatography and flow injection analysis using the self-assembled n-alkanethiol monolayer-modified au electrode.analytical chemistry,68(14),2432-2436.
MLA Liu ZM,et al."Improvements in the selectivity of electrochemical detectors for liquid chromatography and flow injection analysis using the self-assembled n-alkanethiol monolayer-modified au electrode".analytical chemistry 68.14(1996):2432-2436.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。