ON THE SIGNIFICANCE OF WAVELENGTH POSITIONING ACCURACY IN MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
文献类型:期刊论文
作者 | YANG JF ; PIAO ZX ; ZENG XJ |
刊名 | spectrochimica acta part b-atomic spectroscopy
![]() |
出版日期 | 1993 |
卷号 | 48期号:4页码:543-551 |
关键词 | SPECTRAL INTERFERENCES SELECTIVITY |
ISSN号 | 0584-8547 |
通讯作者 | yang jf |
中文摘要 | the present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (icp-aes). using scanning spectrometers commercially available today, a large relative error, delta(a) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. the emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. a quantitative relation between delta(a) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of gaussian line profiles. the agreement between calculated and experimental delta(a) is also illustrated. the delta(a) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where delta(a) decreases with an increase in the ratio. compared with dlambda, the effect of deltalambda is generally less significant. |
收录类别 | SCI收录期刊论文 |
语种 | 英语 |
公开日期 | 2011-01-19 ; 2011-06-10 |
源URL | [http://ir.ciac.jl.cn/handle/322003/36215] ![]() |
专题 | 长春应用化学研究所_长春应用化学研究所知识产出_期刊论文 |
推荐引用方式 GB/T 7714 | YANG JF,PIAO ZX,ZENG XJ. ON THE SIGNIFICANCE OF WAVELENGTH POSITIONING ACCURACY IN MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY[J]. spectrochimica acta part b-atomic spectroscopy,1993,48(4):543-551. |
APA | YANG JF,PIAO ZX,&ZENG XJ.(1993).ON THE SIGNIFICANCE OF WAVELENGTH POSITIONING ACCURACY IN MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY.spectrochimica acta part b-atomic spectroscopy,48(4),543-551. |
MLA | YANG JF,et al."ON THE SIGNIFICANCE OF WAVELENGTH POSITIONING ACCURACY IN MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY".spectrochimica acta part b-atomic spectroscopy 48.4(1993):543-551. |
入库方式: OAI收割
来源:长春应用化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。