中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
WAVELENGTH POSITIONING ERRORS AND TRUE DETECTION LIMIT IN RELATION TO MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

文献类型:期刊论文

作者YANG JF ; PIAO ZX ; ZENG XJ
刊名spectrochimica acta part b-atomic spectroscopy
出版日期1993
卷号48期号:3页码:359-372
关键词SPECTRAL INTERFERENCES ICP-AES SELECTIVITY RESOLUTION BANDWIDTH
ISSN号0584-8547
通讯作者yang jf
中文摘要the present paper deals with the evaluation of the relative error (delta(a)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (mca) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. in the theoretical part, a quantitative relation of delta(a) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of gaussian line profiles. the measurements of eleven samples covering various typical line interferences showed that the calculated delta(a) generally agrees well with the experimental one. an expression of the true detection limit associated with mca techniques was thus formulated. with mca techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. therefore. a given positioning error results in a larger delta(a) and hence a higher true detection limit in the case of mca techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. in the light of the effect of wavelength positioning errors, mca techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.
收录类别SCI收录期刊论文
语种英语
公开日期2011-01-19 ; 2011-06-10
源URL[http://ir.ciac.jl.cn/handle/322003/36243]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
YANG JF,PIAO ZX,ZENG XJ. WAVELENGTH POSITIONING ERRORS AND TRUE DETECTION LIMIT IN RELATION TO MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY[J]. spectrochimica acta part b-atomic spectroscopy,1993,48(3):359-372.
APA YANG JF,PIAO ZX,&ZENG XJ.(1993).WAVELENGTH POSITIONING ERRORS AND TRUE DETECTION LIMIT IN RELATION TO MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY.spectrochimica acta part b-atomic spectroscopy,48(3),359-372.
MLA YANG JF,et al."WAVELENGTH POSITIONING ERRORS AND TRUE DETECTION LIMIT IN RELATION TO MULTICOMPONENT ANALYSIS TECHNIQUES FOR THE CORRECTION OF LINE INTERFERENCES IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY".spectrochimica acta part b-atomic spectroscopy 48.3(1993):359-372.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。