中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
SENSITIVE AMPEROMETRIC DETECTION OF GLUCOSE BY REVERSED PHASE LIQUID-CHROMATOGRAPHY AT A PRUSSIAN BLUE CHEMICALLY MODIFIED ELECTRODE OF NOVEL CONSTRUCTION

文献类型:期刊论文

作者ZHOU JX ; WANG E
刊名journal of electroanalytical chemistry
出版日期1992
卷号331期号:1-2页码:1029-1043
关键词PLATINUM-ELECTRODES ENZYME ELECTRODES FLOW-INJECTION ELECTROCHEMICAL DETECTION GRAPHITE ELECTRODE POTENTIAL WAVEFORM OXIDASE SENSOR GOLD ELECTROCATALYSIS
ISSN号0022-0728
中文摘要a new liquid chromatography electrochemical (lcec) scheme for glucose sensing has been developed on the basis of a prussian blue chemically modified electrode (cme) of novel construction and characterized in terms of various experimental parameters by the flow injection analysis (fia) technique. unique hydrodynamic voltammograms were obtained for the first time at the cme in the flow-through amperometric detection of glucose, and subsequently both anodic and cathodic peaks could be expected on monitoring the operating potential in the modest positive or negative region. the unique ph dependence on the cme response towards glucose makes it perfectly compatible with conventional reversed phase liquid chromatography systems. on the basis of these features, practical application in glucose lcec detection has been effectively performed; a linear response range over three orders of magnitude and a detection limit of subpicomole level were readily obtained. the capability of the established lcec mode in the direct sensing of urinary glucose has been demonstrated.
收录类别SCI收录期刊论文
语种英语
公开日期2011-01-19 ; 2011-06-10
源URL[http://ir.ciac.jl.cn/handle/322003/37211]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
ZHOU JX,WANG E. SENSITIVE AMPEROMETRIC DETECTION OF GLUCOSE BY REVERSED PHASE LIQUID-CHROMATOGRAPHY AT A PRUSSIAN BLUE CHEMICALLY MODIFIED ELECTRODE OF NOVEL CONSTRUCTION[J]. journal of electroanalytical chemistry,1992,331(1-2):1029-1043.
APA ZHOU JX,&WANG E.(1992).SENSITIVE AMPEROMETRIC DETECTION OF GLUCOSE BY REVERSED PHASE LIQUID-CHROMATOGRAPHY AT A PRUSSIAN BLUE CHEMICALLY MODIFIED ELECTRODE OF NOVEL CONSTRUCTION.journal of electroanalytical chemistry,331(1-2),1029-1043.
MLA ZHOU JX,et al."SENSITIVE AMPEROMETRIC DETECTION OF GLUCOSE BY REVERSED PHASE LIQUID-CHROMATOGRAPHY AT A PRUSSIAN BLUE CHEMICALLY MODIFIED ELECTRODE OF NOVEL CONSTRUCTION".journal of electroanalytical chemistry 331.1-2(1992):1029-1043.

入库方式: OAI收割

来源:长春应用化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。