中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
The progress of pulsed optically pumped rubidium clock at SIOM

文献类型:会议论文

作者Dong, Gongxun; Deng, Jianliao; Lin, Jinda; Zhang, Song; Wang, Yuzhu
出版日期2016
英文摘要In this paper, we present a laboratory prototype of POP atomic clock with dispersive detection developed at Shanghai Institute of Optics and Fine Mechanics (SIOM). A new physics package is designed in order to improve the homogeneity of the H-field orientation. The Ramsey fringe is presented with an ultrahigh contrast of 91% and line-width of 130 Hz. A clock frequency stability of 6.14 × 10-13@1 s is obtained and the level of 2 × 10-14is achieved at an average time of τ = 1000 s. ? 2016 IEEE.
会议录2016 Progress In Electromagnetics Research Symposium, PIERS 2016 - Proceedings
语种英语
源URL[http://ir.siom.ac.cn/handle/181231/27441]  
专题上海光学精密机械研究所_量子光学重点实验室
作者单位中国科学院上海光学精密机械研究所
推荐引用方式
GB/T 7714
Dong, Gongxun,Deng, Jianliao,Lin, Jinda,et al. The progress of pulsed optically pumped rubidium clock at SIOM[C]. 见:.

入库方式: OAI收割

来源:上海光学精密机械研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。