Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives
文献类型:期刊论文
作者 | Sun Qi1; Liu Ji-Wei1; Peng Li-Ying2,3; Huang Wei2; Wang Wei-Guo2; Jiang Dan-Dan2,3; Li Hai-Yang2 |
刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
![]() |
出版日期 | 2016-08-01 |
卷号 | 44期号:8页码:1185-1192 |
关键词 | Ion mobility spectrometry Explosives Ionization source Negative corona discharge Unidirectional mode |
英文摘要 | Ion mobility spectrometry (IMS) based explosives detectors is wieldy deployed at the check points of airport, etc, so the development of new ionization method to replace the radioactive Ni-63 ion source in IMS is highly demanded. In this study, a novel negative corona discharge was developed for ion mobility spectrometer for rapid detection of trace explosives, which was running in the unidirectional mode to efficiently remove nitrogen oxides and ozone produced from the discharge process. The diameter of target electrode was 3 mm, the distance between the needle and the target electrode was 2 mm, the discharge voltage was 2400 V and the flow rate of drift gas was 1200 mL/min. Under the optimized conditions, the dominant reactant ions was O-2(H2O)(n) and could be used to directly detect the common explosives, such as trinitrotoluene (TNT), ammonium nitrate (AN), nitroglycerin (NG), pentaerythritol tetranitrate (PETN) and hexahydro. 1,3,5-trinitro. 1,3,5-triazine (RDX). The limit of detection of TNT was 200 pg/mu L. These results indicated that negative corona discharge ionization source, with the advantanges of the high sensibility, simple structure and no radioactivity, could be used as a potential and promising ionization source for ion mobility spectrometry to detect explosives. |
WOS标题词 | Science & Technology ; Physical Sciences |
类目[WOS] | Chemistry, Analytical |
关键词[WOS] | IONIZATION SOURCE ; SENSITIVE DETECTION ; MASS-SPECTROMETRY ; RAPID DETECTION ; MICROEXTRACTION ; WATER ; AIR |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000389035300004 |
源URL | [http://cas-ir.dicp.ac.cn/handle/321008/150352] ![]() |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Liaoning Normal Univ, Fac Chem & Chem Engn, Inst Chem Functionalized Mat, Dalian 116029, Peoples R China 2.Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China 3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Sun Qi,Liu Ji-Wei,Peng Li-Ying,et al. Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2016,44(8):1185-1192. |
APA | Sun Qi.,Liu Ji-Wei.,Peng Li-Ying.,Huang Wei.,Wang Wei-Guo.,...&Li Hai-Yang.(2016).Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,44(8),1185-1192. |
MLA | Sun Qi,et al."Development of Unidirectional Negative Corona Discharge Ion Mobility Spectrometer for Detection of Explosives".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 44.8(2016):1185-1192. |