Measurements of line strengths for some lines of ammonia in 6611-6618 cm(-1)

文献类型:期刊论文

作者Nie Wei1,2; Kan Rui-Feng1; Xu Zhen-Yu1; Yang Chen-Guang1; Chen Bing1; Xia Hui-Hui1,2; Wei Min1,2; Chen Xiang1,2; Yao Lu1; Li Hang1,2
刊名ACTA PHYSICA SINICA
出版日期2017-03-05
卷号66期号:5页码:1-8
关键词Ammonia Tunable Diode Laser Absorption Spectroscopy Line Strengths Uncertainties
DOI10.7498/aps.66.054207
文献子类Article
英文摘要The target gas molecular absorption spectrum parameters especially line strengths are very important for measuring temperature and concentration with tunable diode laser absorption spectroscopy (TDLAS) technique. Usually, researchers use line strengths which come from spectrum database, like HITRAN and GEISA and HITEMP spectra database, but those database include values from the theoretical computation, as is well known, there is a big error between the theoretical value and the actual value. In order to modify the line strengths of the database, 20 ammonia spectrum absorption lines in a wavenumber range between 6611 and 6618 cm(-1) are measured at different pressures by using direct tunable diode laser absorption spectroscopy (dTDLAS) technique. The measurement procedure is repeated at least 10 times at each pressure, and then average value is calculated. Voigt fitting is used to obtain all line integral area, and then the line integral area is obtained by linear fitting. The slope of the fitting straight line equals line strength. Uncertainty analysis is given for the measurements. The measured linestrength is a function of integrated area, temperature, pressure, species mole fraction and effective path length. So, the calculated linestrength uncertainties based on those parameters uncertainties, and the uncertainties of pressure, species mole fraction and effective path length are similar for all transitions with Delta(P) = 0.25%, Delta(chi) = 0.2%, and Delta(L) = 0.4%. The uncertainties of the integrated area and temperature are related to different lines, and their values come from the actual measurement. In the end, uncertainty propagation formula is used to calculate linestrength uncetainty. Uncertainties of our measured line strengths are in a 0.81%-3.33% range. Our measured line strength values are different from line strengths in the HITRAN 2012 database, and the deviations are in 0.51%-17.28% range.
WOS关键词MU-M ; BROADENING COEFFICIENTS ; ABSORPTION-SPECTROSCOPY ; NH3 ; TRANSITIONS ; DATABASE ; REGION ; LASERS ; BAND
WOS研究方向Physics
语种英语
WOS记录号WOS:000398071700014
资助机构National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537) ; National Key Scientific Instrument and Equipment Development Project of China(2014YQ060537)
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/31805]  
专题合肥物质科学研究院_中科院安徽光学精密机械研究所
作者单位1.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
Nie Wei,Kan Rui-Feng,Xu Zhen-Yu,et al. Measurements of line strengths for some lines of ammonia in 6611-6618 cm(-1)[J]. ACTA PHYSICA SINICA,2017,66(5):1-8.
APA Nie Wei.,Kan Rui-Feng.,Xu Zhen-Yu.,Yang Chen-Guang.,Chen Bing.,...&Hu Jia-Yi.(2017).Measurements of line strengths for some lines of ammonia in 6611-6618 cm(-1).ACTA PHYSICA SINICA,66(5),1-8.
MLA Nie Wei,et al."Measurements of line strengths for some lines of ammonia in 6611-6618 cm(-1)".ACTA PHYSICA SINICA 66.5(2017):1-8.

入库方式: OAI收割

来源:合肥物质科学研究院

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。