An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)
文献类型:期刊论文
作者 | Jiang, Lin1,2,3; Wang, Yuane1,2,3; Ding, Jiawang1,3![]() ![]() |
刊名 | ELECTROCHEMISTRY COMMUNICATIONS
![]() |
出版日期 | 2010-02-01 |
卷号 | 12期号:2页码:202-205 |
关键词 | Ionophore Nafion Bismuth Electrode Cadmium Stripping Voltammetry |
产权排序 | [Jiang, Lin; Wang, Yuane; Ding, Jiawang; Lou, Tingting; Qin, Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China; [Jiang, Lin; Wang, Yuane; Lou, Tingting] Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China; [Jiang, Lin; Wang, Yuane; Ding, Jiawang; Lou, Tingting] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China; [Qin, Wei] Yantai Univ, Sch Oceanol, Yantai 264005, Peoples R China |
通讯作者 | Qin, W, Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China |
文献子类 | Article |
英文摘要 | A novel ionophore-Nafion modified bismuth electrode is described for sensitive and selective anodic stripping analysis of cadmium(II). The electrode is prepared by coating the glassy carbon electrode with the cadmium ionophore N,N,N',N'-tetrabutyl-3,6-dioxaoctanedi(thioamide) and Nafion composite. Bismuth is deposited in situ on the electrode surface by plating simultaneously with cadmium in sample solution. Numerous key variables affecting the current response of cadmium have been optimized. The electrode has a linear concentration range of 0.5-10 nM with a deposition time of 180 s. The detection limit is 1.3 x 10(-10) M and the relative standard deviations for 0.5 and 7 nM cadmium are 6.5% and 4.5%, respectively. The proposed electrode shows excellent selectivity over other heavy metals, such as copper, lead and indium. The attractive performance of such electrode offers a feasible way to monitor trace cadmium(II) rapidly and precisely in complex matrixes. (C) 2009 Elsevier B.V. All rights reserved.; A novel ionophore-Nafion modified bismuth electrode is described for sensitive and selective anodic stripping analysis of cadmium(II). The electrode is prepared by coating the glassy carbon electrode with the cadmium ionophore N,N,N',N'-tetrabutyl-3,6-dioxaoctanedi(thioamide) and Nafion composite. Bismuth is deposited in situ on the electrode surface by plating simultaneously with cadmium in sample solution. Numerous key variables affecting the current response of cadmium have been optimized. The electrode has a linear concentration range of 0.5-10 nM with a deposition time of 180 s. The detection limit is 1.3 x 10(-10) M and the relative standard deviations for 0.5 and 7 nM cadmium are 6.5% and 4.5%, respectively. The proposed electrode shows excellent selectivity over other heavy metals, such as copper, lead and indium. The attractive performance of such electrode offers a feasible way to monitor trace cadmium(II) rapidly and precisely in complex matrixes. (C) 2009 Elsevier B.V. All rights reserved. |
学科主题 | Electrochemistry |
WOS关键词 | ANODIC-STRIPPING VOLTAMMETRY ; FILM ELECTRODES ; CARBON ELECTRODES ; TRACE-METALS ; LEAD ; MEMBRANE |
WOS研究方向 | Electrochemistry |
语种 | 英语 |
WOS记录号 | WOS:000274878400007 |
资助机构 | Chinese Academy of Sciences [KZCX2-YW-410]; National Natural Science Foundation of China [40776058]; National 863 High Technology Project of the Ministry of Science and Technology of China [2007AA09Z103]; Scientific Research Foundation ; Department of Science and Technology of Shandong Province [2006GG2205033]; Outstanding Youth Natural Science Foundation of Shandong Province [JQ200814]; Taishan Scholar Program of Shandong Province |
源URL | [http://ir.yic.ac.cn/handle/133337/3708] ![]() |
专题 | 烟台海岸带研究所_近岸生态与环境实验室 |
作者单位 | 1.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Environm Proc, Yantai 264003, Peoples R China 2.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China 3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China 4.Yantai Univ, Sch Oceanol, Yantai 264005, Peoples R China |
推荐引用方式 GB/T 7714 | Jiang, Lin,Wang, Yuane,Ding, Jiawang,et al. An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)[J]. ELECTROCHEMISTRY COMMUNICATIONS,2010,12(2):202-205. |
APA | Jiang, Lin,Wang, Yuane,Ding, Jiawang,Lou, Tingting,&Qin, Wei.(2010).An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II).ELECTROCHEMISTRY COMMUNICATIONS,12(2),202-205. |
MLA | Jiang, Lin,et al."An ionophore-Nafion modified bismuth electrode for the analysis of cadmium(II)".ELECTROCHEMISTRY COMMUNICATIONS 12.2(2010):202-205. |
入库方式: OAI收割
来源:烟台海岸带研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。