中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Potentiometric Sensor Based on Molecularly Imprinted Polymers for Rapid Determination of Clenbuterol in Pig Urine

文献类型:期刊论文

作者Liang Rong-Ning1; Gao Qi1,2; Qin Wei1
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
出版日期2012-03-01
卷号40期号:3页码:354-358
关键词Molecularly Imprinted Polymer Potentiometric Sensor Clenbuterol
ISSN号0253-3820
产权排序[Liang Rong-Ning; Gao Qi; Qin Wei] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Prov Key Lab Coastal Zone Environm Proc, Key Lab Coastal Zone Environm Proc,YICCAS, Yantai 264003, Shandong, Peoples R China; [Gao Qi] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
通讯作者Qin, W (reprint author), Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Prov Key Lab Coastal Zone Environm Proc, Key Lab Coastal Zone Environm Proc,YICCAS, Yantai 264003, Shandong, Peoples R China. wqin@yic.ac.cn
文献子类Article
英文摘要A polymeric membrane ion-selective electrode for determination of clenbuterol is described. It is based on a molecularly imprinted polymer as an ionophore for molecular recognition, which can be synthesized by precipitation polymerization using clenbuterol hydrochloride as the template molecule. Under optimized conditions, the proposed membrane electrode exhibits Nernstian response to the protonated clenbuterol over the concentration range of 1.0 x 10(-7) M to 1.0 x 10(-4) M with a slope of 55.7 mV/dec., and a detection limit of 7.0 x 10(-8) M. The MIP-based sensor shows excellent selectivity, rapid response time and satisfactory long-term stability. The potentiometric sensor has been successfully applied to the determination of clenbuterol in pig urine samples with recoveries between 98% and 107% and an analysis time of less than 3 min.; A polymeric membrane ion-selective electrode for determination of clenbuterol is described. It is based on a molecularly imprinted polymer as an ionophore for molecular recognition, which can be synthesized by precipitation polymerization using clenbuterol hydrochloride as the template molecule. Under optimized conditions, the proposed membrane electrode exhibits Nernstian response to the protonated clenbuterol over the concentration range of 1.0 x 10(-7) M to 1.0 x 10(-4) M with a slope of 55.7 mV/dec., and a detection limit of 7.0 x 10(-8) M. The MIP-based sensor shows excellent selectivity, rapid response time and satisfactory long-term stability. The potentiometric sensor has been successfully applied to the determination of clenbuterol in pig urine samples with recoveries between 98% and 107% and an analysis time of less than 3 min.
学科主题Chemistry
URL标识查看原文
WOS关键词LIQUID-CHROMATOGRAPHY ; RESIDUAL CLENBUTEROL ; MASS-SPECTROMETRY ; GAS ; ELECTRODES ; LIVER ; ION
WOS研究方向Chemistry
语种英语
WOS记录号WOS:000302781500004
资助机构National Natural Science Foundation of China[20977073]; Outstanding Youth Natural Science Foundation of Shandong Province[JQ200814]; Taishan Scholar Program of Shandong Province, China
公开日期2012-06-13
源URL[http://ir.yic.ac.cn/handle/133337/5526]  
专题烟台海岸带研究所_近岸生态与环境实验室
作者单位1.Chinese Acad Sci, Yantai Inst Coastal Zone Res, Shandong Prov Key Lab Coastal Zone Environm Proc, Key Lab Coastal Zone Environm Proc,YICCAS, Yantai 264003, Shandong, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Liang Rong-Ning,Gao Qi,Qin Wei. Potentiometric Sensor Based on Molecularly Imprinted Polymers for Rapid Determination of Clenbuterol in Pig Urine[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2012,40(3):354-358.
APA Liang Rong-Ning,Gao Qi,&Qin Wei.(2012).Potentiometric Sensor Based on Molecularly Imprinted Polymers for Rapid Determination of Clenbuterol in Pig Urine.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,40(3),354-358.
MLA Liang Rong-Ning,et al."Potentiometric Sensor Based on Molecularly Imprinted Polymers for Rapid Determination of Clenbuterol in Pig Urine".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 40.3(2012):354-358.

入库方式: OAI收割

来源:烟台海岸带研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。