中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
热门
Resolution limit of anisotropic magnetoresistance(AMR) based vector magnetometer

文献类型:期刊论文

作者Qiu, Fuwei1,2; Wang, Jindong1; Zhang, Yiteng1; Yang, Gen3; Weng, Chenghan1
刊名SENSORS AND ACTUATORS A-PHYSICAL
出版日期2018
卷号280页码:61-67
关键词AMR Resolution Noise Magnetoresistive magnetometer
ISSN号0924-4247
DOI10.1016/j.sna.2018.07.031
英文摘要An AMR based vector magnetometer was developed for the Separated Payload program to explore the field-aligned currents in Earth polar region. It has the advantages of low volume and CubeSat platform compatible mass while still maintains adequate resolution. In order to determine the resolution limit of AMR based magnetometer, we measured the sensor's intrinsic noise. This characteristic was in conflict with our prototype magnetoresistive magnetometer since phase sensitive detection(PSD) could only reject noise from interfacing circuit without affecting the signal to be measured. We believe that besides flipping the magnetization direction periodically, the set/reset technique also functions as a modulation to the magnetic field. The sensor operates at the modulation frequency and its noise level is much lower than that at low frequency. This technique is analyzed theoretically and a description from frequency perspective is given. By modulating the signal beyond corner frequency of the sensor and amplifier, both the sensor and interfacing circuit work in white noise region. Then we calculate the theoretical resolution limit of HMC1001 based magnetometer and the result shows that the noise floor is 24.9 pT/Hz(0.5)@1 Hz under 5 V bias with proper -matched amplifier. (C) 2018 Elsevier B.V. All rights reserved.
语种英语
源URL[http://ir.nssc.ac.cn/handle/122/6548]  
专题国家空间科学中心_空间科学部
作者单位1.State Key Laboratory of Space Weather, National Space Science Center, Chinese Academy of Sciences, Beijing, China;
2.University of Chinese Academy of Sciences, Beijing, China;
3.Key laboratory of electronics and information technology for space systems, National Space Science Center, Chinese Academy of Sciences, Beijing, China
推荐引用方式
GB/T 7714
Qiu, Fuwei,Wang, Jindong,Zhang, Yiteng,et al. Resolution limit of anisotropic magnetoresistance(AMR) based vector magnetometer[J]. SENSORS AND ACTUATORS A-PHYSICAL,2018,280:61-67.
APA Qiu, Fuwei,Wang, Jindong,Zhang, Yiteng,Yang, Gen,&Weng, Chenghan.(2018).Resolution limit of anisotropic magnetoresistance(AMR) based vector magnetometer.SENSORS AND ACTUATORS A-PHYSICAL,280,61-67.
MLA Qiu, Fuwei,et al."Resolution limit of anisotropic magnetoresistance(AMR) based vector magnetometer".SENSORS AND ACTUATORS A-PHYSICAL 280(2018):61-67.

入库方式: OAI收割

来源:国家空间科学中心

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。