A report on a biotite-calcic hornblende geothermometer
文献类型:期刊论文
作者 | Wu, CM; Pan, YS; Wang, KY; Zhang, J |
刊名 | ACTA GEOLOGICA SINICA-ENGLISH EDITION
![]() |
出版日期 | 2002-03-01 |
卷号 | 76期号:1页码:126-131 |
关键词 | biotite-calcic hornblende geothermometer calibration random error application |
ISSN号 | 1000-9515 |
文献子类 | Article |
英文摘要 | This paper presents a biotite-calcic hornblende geothermometer which was empirically calibrated based on the garnet-biotite geothermometer and the gamet-plagioclase-homblende-quartz geobarometer, in the ranges of 560-800degreesC (T) and 0.26-1.4 GPa (P) using the data of metadolerite, amphibolite, metagabbro, and metapelite collected from the literature. Biotite was treated as symmetric Fe-Mg-Al-VI-Ti quaternary solid solution, and calcic homblende was simplified as symmetric Fe-Mg binary solid solution. The resulting thermometer may rebuild the input garnet-biotite temperatures well within an uncertainty of +/-50degreesC. Errors of +/-0.2 GPa for input pressure, along with analytical errors of +/-5% for the relevant mineral compositions, may lead to a random error of +/-16degreesC for this thermometer, so that the thermometer is almost independent of pressure estimates. The thermometer may clearly discriminate different rocks of lower amphibolite, upper amphibolite and granulite facies on a high confidence level. It is assumed that there is a ferric iron content of 11.6% in biotite, and that the iron content in calcic homblende may be calculated according to the method of Dale et al. (2000). This thermometer can be used for medium- to high-grade metabasites and metapelites. |
WOS关键词 | GRANULITE FACIES ; PHASE-EQUILIBRIA ; NEW-HAMPSHIRE ; GARNET ; FE ; MG ; AMPHIBOLITES ; COMPLEX ; VERMONT |
WOS研究方向 | Geology |
语种 | 英语 |
WOS记录号 | WOS:000174604400013 |
出版者 | GEOLOGICAL SOC CHINA |
源URL | [http://ir.iggcas.ac.cn/handle/132A11/78093] ![]() |
专题 | 中国科学院地质与地球物理研究所 |
通讯作者 | Wu, CM |
作者单位 | 1.Chinese Acad Geol Sci, Inst Geol, Beijing 100037, Peoples R China 2.Chinese Acad Sci, Inst Geol & Geophys, Beijing 100029, Peoples R China 3.Chinese Acad Sci, Grad Sch, Dept Earth Sci, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Wu, CM,Pan, YS,Wang, KY,et al. A report on a biotite-calcic hornblende geothermometer[J]. ACTA GEOLOGICA SINICA-ENGLISH EDITION,2002,76(1):126-131. |
APA | Wu, CM,Pan, YS,Wang, KY,&Zhang, J.(2002).A report on a biotite-calcic hornblende geothermometer.ACTA GEOLOGICA SINICA-ENGLISH EDITION,76(1),126-131. |
MLA | Wu, CM,et al."A report on a biotite-calcic hornblende geothermometer".ACTA GEOLOGICA SINICA-ENGLISH EDITION 76.1(2002):126-131. |