中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Determination of free fatty acids in soil and bryophyte plants by precolumn derivatization via HPLC with fluorescence detection and tandem mass spectrometry (HPLC-MS/MS)

文献类型:期刊论文

作者Suo, Yourui; Zhao, Xianen; You, Jinmao; Wang, Honglun; Li, Yulin; Ding, Chenxu; Liu, Yongjun
刊名journal of liquid chromatography & related technologies
出版日期2007
卷号30期号:9-12页码:1811-1831
关键词1-[2-(p-toluenesulfonate)-ethyl]-2-phenylimidazole-[4,5-f]-9,10-phenan- threne (TSPP) derivatization high performance liquid chromatography fluorescence detection fatty acids mass spectrometry
合作状况其它
中文摘要a sensitive method for the determination of 30 kinds of free fatty acids (ffas, c-1-c-30) with 1-[2-(p-toluenesulfonate)-ethyl]-2-phenylimidazole-[4,5-f] 9,10-phenan- threne (tspp) as labeling reagent and using high performance liquid chromatography with fluorescence detection and identification by online postcolumn mass spectrometry with atmospheric pressure chemical ionization (apci) source in positive-ion mode (hplc/ms/apci) has been developed. tspp could easily and quickly label ffas in the presence of k2co3 catalyst at 90 degrees c for 30 min in n,n-dimethylformamide (dmf) solvent, and maximal labeling yields close to 100% were observed with a 5-fold excess of molar reagent. derivatives were stable enough to be efficiently analyzed by high performance liquid chromatography. tspp was introduced into fatty acid molecules and effectively augmented ms ionization of fatty acid derivatives and led to regular ms and ms/ms information. the collision induced cleavage of protonated molecular ions formed specific fragment ions at m/z [mh](+)(molecular ion), m/z [m'+ch2ch2](+)(m' was molecular mass of the corresponding ffa) and m/z 295.0 (the, mass of protonated molecular core structure of tspp). fatty acid derivatives were separated on a reversed-phase eclipse xdb-c-8 column (4.6 x 150 mm, 5 mu m, agilent) with a good baseline resolution in combination with a gradient elution. linear ranges of 30 ffas are 2.441 x 10(-3) to 20 mu mol/l, detection limits are 3.24 similar to 36.97 fmol (injection volume 10 mu l, at a signal-to-noise ratio of 3, s/n 3:1). the mean interday precision ranged from 93.4 to 106.2% with the largest mean coefficients of variation (r.s.d.) < 7,5%. the mean intraday precision for all standards was < 6.4% of the expected concentration. excellent linear responses were observed with correlation coefficients of > 0.9991. good compositional data could be obtained from the analysis of extracted fatty acids from as little as 200 mg of bryophyte plant samples.therefore, the facile tspp derivatization coupled with hplc/ms/apci analysis allowed the development of a highly sensitive method for the quantitation of trace levels of short and long chain fatty acids from biological and natural environmental samples.
英文摘要a sensitive method for the determination of 30 kinds of free fatty acids (ffas, c-1-c-30) with 1-[2-(p-toluenesulfonate)-ethyl]-2-phenylimidazole-[4,5-f] 9,10-phenan- threne (tspp) as labeling reagent and using high performance liquid chromatography with fluorescence detection and identification by online postcolumn mass spectrometry with atmospheric pressure chemical ionization (apci) source in positive-ion mode (hplc/ms/apci) has been developed. tspp could easily and quickly label ffas in the presence of k2co3 catalyst at 90 degrees c for 30 min in n,n-dimethylformamide (dmf) solvent, and maximal labeling yields close to 100% were observed with a 5-fold excess of molar reagent. derivatives were stable enough to be efficiently analyzed by high performance liquid chromatography. tspp was introduced into fatty acid molecules and effectively augmented ms ionization of fatty acid derivatives and led to regular ms and ms/ms information. the collision induced cleavage of protonated molecular ions formed specific fragment ions at m/z [mh](+)(molecular ion), m/z [m'+ch2ch2](+)(m' was molecular mass of the corresponding ffa) and m/z 295.0 (the, mass of protonated molecular core structure of tspp). fatty acid derivatives were separated on a reversed-phase eclipse xdb-c-8 column (4.6 x 150 mm, 5 mu m, agilent) with a good baseline resolution in combination with a gradient elution. linear ranges of 30 ffas are 2.441 x 10(-3) to 20 mu mol/l, detection limits are 3.24 similar to 36.97 fmol (injection volume 10 mu l, at a signal-to-noise ratio of 3, s/n 3:1). the mean interday precision ranged from 93.4 to 106.2% with the largest mean coefficients of variation (r.s.d.) < 7,5%. the mean intraday precision for all standards was < 6.4% of the expected concentration. excellent linear responses were observed with correlation coefficients of > 0.9991. good compositional data could be obtained from the analysis of extracted fatty acids from as little as 200 mg of bryophyte plant samples.
学科主题生物化学
WOS标题词science & technology ; life sciences & biomedicine ; physical sciences
类目[WOS]biochemical research methods ; chemistry, analytical
研究领域[WOS]biochemistry & molecular biology ; chemistry
关键词[WOS]performance liquid-chromatography ; carboxylic-acids ; labeling reagent ; trifluoromethanesulfonate ; identification ; derivatives ; liverworts ; japanese ; 9-anthryldiazomethane ; serum
收录类别SCI
语种英语
WOS记录号WOS:000246884000043
公开日期2009-12-07
源URL[http://ir.nwipb.ac.cn/handle/363003/1273]  
专题西北高原生物研究所_中国科学院西北高原生物研究所
作者单位Chinese Acad Sci, NW Plateau Inst Biol, Xining 810001, Peoples R China
推荐引用方式
GB/T 7714
Suo, Yourui,Zhao, Xianen,You, Jinmao,et al. Determination of free fatty acids in soil and bryophyte plants by precolumn derivatization via HPLC with fluorescence detection and tandem mass spectrometry (HPLC-MS/MS)[J]. journal of liquid chromatography & related technologies,2007,30(9-12):1811-1831.
APA Suo, Yourui.,Zhao, Xianen.,You, Jinmao.,Wang, Honglun.,Li, Yulin.,...&Liu, Yongjun.(2007).Determination of free fatty acids in soil and bryophyte plants by precolumn derivatization via HPLC with fluorescence detection and tandem mass spectrometry (HPLC-MS/MS).journal of liquid chromatography & related technologies,30(9-12),1811-1831.
MLA Suo, Yourui,et al."Determination of free fatty acids in soil and bryophyte plants by precolumn derivatization via HPLC with fluorescence detection and tandem mass spectrometry (HPLC-MS/MS)".journal of liquid chromatography & related technologies 30.9-12(2007):1811-1831.

入库方式: OAI收割

来源:西北高原生物研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。