Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array

文献类型:期刊论文

作者Zhang Y(张颖); Huang J(黄晶); Chen X(陈旭); Hu XB(胡孝斌); Lin YH(林钰晖); Zhang, Y; Huang, J; Chen, D; Zhai, LM; Chen, X
刊名JOURNAL OF INSTRUMENTATION
出版日期2016
卷号11
关键词Cherenkov detectors Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others)
DOI10.1088/1748-0221/11/06/P06016
通讯作者张颖(天
英文摘要Since 2014, a new hybrid experiment consisting of a high-energy air-shower-core array (YAC-II), a high-density air-shower array (Tibet-III) and a large underground water-Cherenkov muon-detector array (MD) has been continued by the Tibet AS gamma collaboration to measure the chemical composition of cosmic rays in the wide energy range including the "knee". In this experiment, YAC-II is used to select high energy core events induced by cosmic rays in the above energy region, while MD is used to estimate the type of nucleus of primary particles by measuring the number of muons contained in the air showers. However, the dynamic range of each MD cell is only 5 to 2000 photoelectrons (PEs) which is mainly designed for observation of high-energy celestial gamma rays. In order to obtain the primary proton, helium and iron spectra and their "knee" positions with energy up to 1016 eV, each of PMTs equipped to the MD cell is required to measure the number of photons capable of covering a wide dynamic range of 100-106 PEs according to Monte Carlo simulations. In this paper, we firstly compare the characteristic features between R5912-PMT made by Japan Hamamatsu and CR365-PMT made by Beijing Hamamatsu. If there exists no serious difference, we will then add two 8-inch-in-diameter PMTs to meet our requirements in each MD cell, which are responsible for the range of 100-10000 PEs and 2000-1000000 PEs, respectively. That is, MD cell is expected to be able to measure the number of muons over 6 orders of magnitudes.
语种英语
WOS记录号WOS:000379239700028
源URL[http://ir.ihep.ac.cn/handle/311005/260848]  
专题中国科学院高能物理研究所
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Zhang Y,Huang J,Chen X,et al. Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array[J]. JOURNAL OF INSTRUMENTATION,2016,11.
APA 张颖.,黄晶.,陈旭.,胡孝斌.,林钰晖.,...&Zhaxiciren.(2016).Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array.JOURNAL OF INSTRUMENTATION,11.
MLA 张颖,et al."Performance of new 8-inch photomultiplier tube used for the Tibet muon-detector array".JOURNAL OF INSTRUMENTATION 11(2016).

入库方式: OAI收割

来源:高能物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。