中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Estimation of low-dose-rate degradation on bipolar linear circuits using different accelerated evaluation methods

文献类型:期刊论文

作者Li, XL (Li Xiao-Long)[ 1,2,3 ]; Lu, W (Lu Wu)[ 1,2 ]; Wang, X (Wang Xin)[ 1,2,3 ]; Guo, Q (Guo Qi)[ 1,2 ]; He, CF (He Cheng-Fa)[ 1,2 ]; Sun, J (Sun Jing)[ 1,2 ]; Yu, X (Yu Xin)[ 1,2 ]; Liu, MH (Liu Mo-Han)[ 1,2,3 ]; Jia, JC (Jia Jin-Cheng)[ 1,2,3 ]; Yao, S (Yao Shuai)[ 1,2,3 ]
刊名ACTA PHYSICA SINICA
出版日期2018
卷号67期号:9页码:202-209
关键词Bipolar Circuit Enhanced Low-dose-rate Sensitivity Accelerated Evaluation Method
ISSN号1000-3290
DOI10.7498/aps.67.20180027
英文摘要

The linear bipolar devices and integrated circuits (ICs) which are subjected to ionizing radiation exhibit parametric degradations due to current-gain decrease, and the amount of degradation on various types of bipolar devices is much more significant at low-dose-rate than at high-dose-rate. Such an enhanced low-dose-rate sensitivity (ELDRS) is considered to be one of the major challenges for radiation-tolerance testing intended for space systems. Therefore, it is of great significance to explore an efficient and practical test for the ELDRS in the linear bipolar devices and ICs. The different experiments have been implemented on four types of bipolar ICs for evaluating their responses to low-dose-rate irradiation. The experiments involve the dose rate switching approach performed under high to low-dose-rate irradiation and temperature switching approach performed under high to low temperature irradiation. Good agreement is observed between predictive curves obtained at dose rate switching irradiation and the low-dose-rate results, and the irradiation time for the dose rate switching approach is reduced from 4 months to a week. Further, the results also suggest that the device degradation rate can affect the prediction of the total dose. This is because the curves examined at different doses have a lot of overlap when the devices with fast degradation rates are performed. In addition to temperature switching irradiation, the radiation response of the same type of device is much more significant than that obtained in low-dose rate irradiation, and this method will shorten the irradiation time to 12 h. Based on the analysis of mechanisms behind the switched dose rate and temperature irradiation, switching temperature irradiation can accelerate the release of protons and buildup of interface traps, which is the key physical mechanism for ELDRS. Firstly, a higher irradiation temperature can enhance the transport of holes and release of protons to form interface traps, resulting in the enhanced degradation occurring at first dose examined. Further, the reducing temperature sequence suppresses the hydrogen dimerization process during the irradiation that follows, which is strongly temperature dependent and contributes to interface trap annealing. Moreover, further decrease in temperature can restrict the interface trap annealing because the barrier for this process is higher and it has less opportunity to take place at lower temperature. Additionally, the hydrogen molecules converted from hydrogen dimerization may extend the liberation of protons, by the hydrogen molecules cracking mechanisms, leading to the additional degradation. Therefore, the temperature switching irradiation is shown to be a conservative and efficient method for ELDRS in bipolar devices, and this provides an insight into hardness assurance testing.

WOS记录号WOS:000443195000021
源URL[http://ir.xjipc.cas.cn/handle/365002/5576]  
专题新疆理化技术研究所_中国科学院特殊环境功能材料与器件重点试验室
新疆理化技术研究所_材料物理与化学研究室
通讯作者Lu, W (Lu Wu)[ 1,2 ]
作者单位1.Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, Key Lab Funct Mat & Devices Special Environm, Urumqi 830011, Peoples R China
2.Xinjiang Key Lab Elect Informat Mat & Device, Urumqi 830011, Peoples R China
3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Li, XL ,Lu, W ,Wang, X ,et al. Estimation of low-dose-rate degradation on bipolar linear circuits using different accelerated evaluation methods[J]. ACTA PHYSICA SINICA,2018,67(9):202-209.
APA Li, XL .,Lu, W .,Wang, X .,Guo, Q .,He, CF .,...&Wei, XY .(2018).Estimation of low-dose-rate degradation on bipolar linear circuits using different accelerated evaluation methods.ACTA PHYSICA SINICA,67(9),202-209.
MLA Li, XL ,et al."Estimation of low-dose-rate degradation on bipolar linear circuits using different accelerated evaluation methods".ACTA PHYSICA SINICA 67.9(2018):202-209.

入库方式: OAI收割

来源:新疆理化技术研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。