中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
In vitro evaluation of a novel pH neutral calcium phosphosilicate bioactive glass that does not require preconditioning prior to use

文献类型:期刊论文

作者Li, Ailing1; Lv, Yang2; Ren, Huihui1,3; Cui, Yang1,3; Wang, Chao1,3; Martin, Richard A.4,5; Qiu, Dong1,3
刊名INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE
出版日期2017-12-01
卷号8期号:4页码:403-411
关键词Bioglass Ph Neutral Sol-gel
英文摘要It is well known that bioactive glasses can cause a significant increase in pH due to the rapid release of calcium and/or sodium ions. Consequently, preconditioning of the glass is usually required prior to surgery to negate the effect of this sudden release of ions. However, preconditioning for several days is far from ideal and also preconditioning is not practical for novel organic/inorganic sol-gel hybrids currently being developed since the organic phase will start to hydrolyze and dissolve. This study describes a bioactive glass that dissolves without causing a significant change in pH from physiologically optimal values and requires no preconditioning prior to use. The bioactivity of the pH neutral glass, hydroxyapatite formation, and cellular responses, are measured and compared directly with results from archetypal 45S5 and S70C30 bioactive glasses. A hydroxyapatite layer was found to rapidly form (within 1day) on the surface of the pH neutral glass upon reacting with simulated body fluid. In addition, improved cell compatibility was observed compared with 45S5 and S70C30 glasses. Therefore, this pH neutral glass has significant potential for bone repair applications.
语种英语
源URL[http://ir.iccas.ac.cn/handle/121111/41304]  
专题化学研究所_高分子物理与化学实验室
作者单位1.Chinese Acad Sci, State Key Lab Polymer Phys & Chem, CAS Res Educ Ctr Excellence Mol Sci, Beijing Natl Lab Mol Sci,Inst Chem, Beijing, Peoples R China
2.Peking Univ, Hosp 3, Orthoped Dept, Beijing, Peoples R China
3.Univ Chinese Acad Sci, Beijing, Peoples R China
4.Aston Univ, Sch Engn & Appl Sci, Aston Inst Mat Res, Birmingham, W Midlands, England
5.Aston Univ, Aston Res Ctr Hlth Ageing, Birmingham, W Midlands, England
推荐引用方式
GB/T 7714
Li, Ailing,Lv, Yang,Ren, Huihui,et al. In vitro evaluation of a novel pH neutral calcium phosphosilicate bioactive glass that does not require preconditioning prior to use[J]. INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE,2017,8(4):403-411.
APA Li, Ailing.,Lv, Yang.,Ren, Huihui.,Cui, Yang.,Wang, Chao.,...&Qiu, Dong.(2017).In vitro evaluation of a novel pH neutral calcium phosphosilicate bioactive glass that does not require preconditioning prior to use.INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE,8(4),403-411.
MLA Li, Ailing,et al."In vitro evaluation of a novel pH neutral calcium phosphosilicate bioactive glass that does not require preconditioning prior to use".INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE 8.4(2017):403-411.

入库方式: OAI收割

来源:化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。