Coupling measurement and correction at the SSRF storage ring
文献类型:会议论文
作者 | Zhang, MZ(张满洲); Hou, J(后接); Li, HH(李浩虎) |
出版日期 | 2011 |
会议日期 | OCT 18-20, 2010 |
会议地点 | Beijing, PEOPLES R CHINA |
页码 | S201 |
英文摘要 | Brightness is an important parameter for 3rd generation light source. Correcting the emittance coupling is a realistic way to increase brightness without any additional equipment in a machine under operation. The main sources of emittance coupling are betatron coupling and vertical dispersion. At the SSRF storage ring, tune split and LOCO are used to measure the respective betatron and emittance coupling. Both of these sources can be corrected by skew quadrupoles. By measuring the skew quadrupole-coupling response matrix, betatron coupling can be changed from 0.014% to 2%. But the vertical dispersion changes at the same time. LOCO can find the suitable setting to correct simultaneously the betatron coupling and vertical dispersion. The emittance coupling can be reduced to 0.17% by this method. More simulations show the potential for smaller emittance coupling if more skew quadrupoles are employed. |
资助机构 | Chinese Phys Soc, Particle Accelerator Branch |
会议录 | 科讨会回忆录
![]() |
会议录出版者 | 科学出版社 |
会议录出版地 | 北京 |
语种 | 英语 |
资助项目 | 应物所课题组 |
ISSN号 | 1674-7348 |
源URL | [http://libsvr.sinap.ac.cn:8080/handle/331007/10264] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2004-2010年 |
推荐引用方式 GB/T 7714 | Zhang, MZ,Hou, J,Li, HH. Coupling measurement and correction at the SSRF storage ring[C]. 见:. Beijing, PEOPLES R CHINA. OCT 18-20, 2010. |