中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm

文献类型:期刊论文

作者Hu, T; Wang, YD; Du, GH; Wang, YZ; Hua, WQ; Deng, BA; Xie, HL; Bian, FG; Xiao, TQ
刊名APPLIED OPTICS
出版日期2017
卷号56期号:30页码:8326-8334
关键词Ordered-subsets Image-reconstruction Bone Nanostructure Brain Ct
ISSN号1559-128X
DOI10.1364/AO.56.008326
文献子类期刊论文
英文摘要Small-angle x-ray scattering computed tomography (SAXS-CT) is a nondestructive method for the nanostructure analysis of heterogeneous materials. However, the limits of a long data acquisition time and vast amounts of data prevent SAXS-CT from becoming a routine experimental method in the applications of synchrotron radiation. In this study, the ordered subsets expectation maximization (OSEM) algorithm is introduced to improve the efficiency of SAXS-CT. To demonstrate the practicability of this method, a systematic simulation and experiments were carried out. The simulation results on a numerical phantom show that the OSEM-based SAXS-CT can effectively eliminate streaking artifacts and improve the efficiency of data acquisition by at least 3 times compared with the filter backprojection algorithm. By compromising the reconstruction speed and image quality, the optimal reconstruction parameters are also given for the image reconstruction in the OSEM-based SAXS-CT experiments. An experiment on a bamboo sample verified the validity of the proposed method with limited projection data. A further experiment on polyethylene demonstrated that the OSEM-based SAXS-CT is able to reveal the local nanoscale information about the crystalline structure and distributional difference inside the sample. In conclusion, the OSEM-based SAXS-CT can significantly improve experimental efficiency, which may promote SAXS-CT becoming a conventional method. (C) 2017 Optical Society of America
WOS关键词ORDERED-SUBSETS ; IMAGE-RECONSTRUCTION ; BONE ; NANOSTRUCTURE ; BRAIN ; CT
语种英语
WOS记录号WOS:000413345300004
源URL[http://ir.sinap.ac.cn/handle/331007/28690]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Hu, T,Wang, YD,Du, GH,et al. Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm[J]. APPLIED OPTICS,2017,56(30):8326-8334.
APA Hu, T.,Wang, YD.,Du, GH.,Wang, YZ.,Hua, WQ.,...&Xiao, TQ.(2017).Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm.APPLIED OPTICS,56(30),8326-8334.
MLA Hu, T,et al."Improving the efficiency of small-angle x-ray scattering computed tomography using the OSEM algorithm".APPLIED OPTICS 56.30(2017):8326-8334.

入库方式: OAI收割

来源:上海应用物理研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。