Reliable electrochemical sensing arsenic(III) in nearly groundwater pH based on efficient adsorption and excellent electrocatalytic ability of AuNPs/CeO2-ZrO2 nanocomposite
文献类型:期刊论文
作者 | Yang, M; Li, PH; Xu, WH; Wei, Y; Li, LN; Huang, YY; Sun, YF; Chen, X; Liu, JH; Huang, XJ |
刊名 | SENSORS AND ACTUATORS B-CHEMICAL
![]() |
出版日期 | 2018 |
卷号 | 255页码:226-234 |
关键词 | Anodic-stripping Voltammetry Glassy-carbon Electrode Gold Nanoparticles Water Samples Trace Arsenic(Iii) Au Nanoparticles High-sensitivity Oxide Adsorbent One-pot Removal |
ISSN号 | 0925-4005 |
DOI | 10.1016/j.snb.2017.07.204 |
文献子类 | 期刊论文 |
英文摘要 | Even though electrochemical analytical tools have been widely investigated for toxic As(III) detection and the achievements have also been so fruitful. However, electroanalysis method with efficient and high anti interference toward As(III) in the original pH of natural water is still scarce and urgent. To this end, in this work, a sensing interface, which was fabricated with AuNPs/CeO2-ZrO2 nanocomposite modified glassy carbon electrode (GCE), was employed for sensitive and accurate analysis of As(III) in the nearly ground-water pH (according to a real groundwater sample collected from Guan Di Ying Village in Togtoh County, pH similar to 8.0) using square wave anodic stripping voltammetry (SWASV). Taking advantages of the strong adsorption ability of CeO2-ZrO2 nanospheres toward As(III) in the pH 8.0 media and the extremely good catalytic activity of AuNPs, under the optimum parameters, the sensitivity and the theoretical limit of detection on the electroanalysis of As(III) were 20.674 mu A ppb(-1) cm(-2) and 0.137 ppb, respectively. Moreover, the proposed method has relatively good anti-interference performance. Interesting, the probable reason for the enhanced sensitivity was tentatively confirmed using X-ray photoelectron spectroscopy (XPS). Finally, the practicability of the raised method has been preliminarily verified by the analysis of As(III) contaminated groundwater. (C) 2017 Elsevier B.V. All rights reserved. |
语种 | 英语 |
WOS记录号 | WOS:000414151800027 |
源URL | [http://ir.sinap.ac.cn/handle/331007/29121] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
作者单位 | 1.Yang, M 2.Li, PH 3.Xu, WH 4.Wei, Y 5.Li, LN 6.Huang, YY 7.Sun, YF 8.Chen, X 9.Liu, JH 10.Huang, XJ |
推荐引用方式 GB/T 7714 | Yang, M,Li, PH,Xu, WH,et al. Reliable electrochemical sensing arsenic(III) in nearly groundwater pH based on efficient adsorption and excellent electrocatalytic ability of AuNPs/CeO2-ZrO2 nanocomposite[J]. SENSORS AND ACTUATORS B-CHEMICAL,2018,255:226-234. |
APA | Yang, M.,Li, PH.,Xu, WH.,Wei, Y.,Li, LN.,...&Huang, XJ.(2018).Reliable electrochemical sensing arsenic(III) in nearly groundwater pH based on efficient adsorption and excellent electrocatalytic ability of AuNPs/CeO2-ZrO2 nanocomposite.SENSORS AND ACTUATORS B-CHEMICAL,255,226-234. |
MLA | Yang, M,et al."Reliable electrochemical sensing arsenic(III) in nearly groundwater pH based on efficient adsorption and excellent electrocatalytic ability of AuNPs/CeO2-ZrO2 nanocomposite".SENSORS AND ACTUATORS B-CHEMICAL 255(2018):226-234. |
入库方式: OAI收割
来源:上海应用物理研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。