Ultrasound Strain Elastography for Breast Lesions Computer-Aided Evaluation With Quantifiable Elastographic Features.
文献类型:期刊论文
作者 | Niu, Li-Li; Zheng, Rong-Qin; Zheng, Hai-Rong; Wang, Cong-Zhi; Qian, Ming; Zhang, Xue; Zeng, Jie; Xiao, Yang |
刊名 | JOURNAL OF ULTRASOUND IN MEDICINE |
出版日期 | 2017 |
文献子类 | 期刊论文 |
英文摘要 | Objectives-To develop and evaluate a set of quantifiable elastographic features based on ultrasound real-time strain elastography (SE) in differentiating between benign and malignant breast lesions. Methods-The SE and conventional B-mode ultrasound images of 226 breast lesions (81 malignant, 145 benign) were obtained from 226 consecutive women. By using a computer-aided tool, four elastographic features (elasticity score, lesion stiffness degree, lesion-to-fat strain ratio, and elastography-to-B-mode lesion area ratio) were respectively calculated and evaluated. Histopathologic results were used as the reference standard. B-mode Breast Imaging Reporting and Data System categorization was used to compare the perfonnances between B-mode ultrasound and SE. Sensitivity, specificity, positive and negative predictive values, and receiver operating characteristic curve analyses were performed to evaluate the diagnostic performances for three data sets (conventional B-mode ultrasound alone, SE features alone, combined SE features). Results-Quantifiable SE features for malignant lesions all showed significantly higher values than those for benign lesions (all P <.001). The evaluation with any individual SE feature significantly improved the specificity in breast lesion differentiation compared with B-mode ultrasound (all P <.001). The logistic regression model combing SE features significantly improved the diagnostic performance compared with B-mode US, with significantly increased specificity (95.2% versus 54.5%; P <.001) and area under the receiver operating characteristic curve 0.988 versus 0.921, P <.001). Conclusions-Computer-aided tool with SE provided further elasticity information for breast characterization. Evaluation using quantifiable SE features showed better diagnostic performance than conventional B-mode ultrasound in breast lesion differentiation. |
URL标识 | 查看原文 |
语种 | 英语 |
源URL | [http://ir.siat.ac.cn:8080/handle/172644/12071] |
专题 | 深圳先进技术研究院_医工所 |
作者单位 | JOURNAL OF ULTRASOUND IN MEDICINE |
推荐引用方式 GB/T 7714 | Niu, Li-Li,Zheng, Rong-Qin,Zheng, Hai-Rong,et al. Ultrasound Strain Elastography for Breast Lesions Computer-Aided Evaluation With Quantifiable Elastographic Features.[J]. JOURNAL OF ULTRASOUND IN MEDICINE,2017. |
APA | Niu, Li-Li.,Zheng, Rong-Qin.,Zheng, Hai-Rong.,Wang, Cong-Zhi.,Qian, Ming.,...&Xiao, Yang.(2017).Ultrasound Strain Elastography for Breast Lesions Computer-Aided Evaluation With Quantifiable Elastographic Features..JOURNAL OF ULTRASOUND IN MEDICINE. |
MLA | Niu, Li-Li,et al."Ultrasound Strain Elastography for Breast Lesions Computer-Aided Evaluation With Quantifiable Elastographic Features.".JOURNAL OF ULTRASOUND IN MEDICINE (2017). |
入库方式: OAI收割
来源:深圳先进技术研究院
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。