中国科学院机构知识库网格
Chinese Academy of Sciences Institutional Repositories Grid
Quantitative comparison of lung physiological parameters in single and multiple breathhold with hyperpolarized xenon magnetic resonance

文献类型:期刊论文

作者Liu,Shiyuan1; Zhang,Zhiying2; Guan,Yu1; Li,Haidong2; Zhao,Xiuchao2; Han,Yeqing2; Ye,Chaohui2; Xia,Yi1; Zhou,Xin2; Sun,Xianping2
刊名Biomedical Physics & Engineering Express
出版日期2016-09-21
卷号2期号:5
关键词hyperpolarized gas imaging MRI 129Xe lung chemical shifit saturation recovery 87.61.-c
ISSN号2057-1976
DOI10.1088/2057-1976/2/5/055013
英文摘要Abstract Hyperpolarized (HP) xenon MR has been an important tool for quantifying the pulmonary structure and gaining functional information by measuring the dynamics of xenon in different lung components, e.g., gas exchange between gaseous xenon in the alveoli and dissolved xenon in tissue/plasma? and red blood cells. Chemical shift saturation recovery is a commonly used pulse sequence to measure the xenon dynamics in the lung globally. However, the effect of the dissolved xenon signal oscillation caused by the cardiac cycle on the physiological parameters of the lung is still unclear. In this study, both single-breathhold (SB) and multiple-breathhold (MB) measurements were used to evaluate these effects in rats, and the data acquired with the MB measurement, which did not have oscillations, served as a reference. The pulmonary physiological parameters were extracted using the model of xenon exchange. The results showed that the physiological parameters derived from SB and MB measurements were not significantly different. These findings have clarified a previously unknown issue and will further promote the design of faster real-time acquisition sequences to quantify structural and functional information about the lung.
语种英语
WOS记录号IOP:2057-1976-2-5-055013
出版者IOP Publishing
源URL[http://ir.wipm.ac.cn/handle/112942/12212]  
专题中国科学院武汉物理与数学研究所
作者单位1.Department of Radiology, Changzheng Hospital of the Second Military Medical University, Shanghai 200003, People’s Republic of China
2.Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, People’s Republic of China
推荐引用方式
GB/T 7714
Liu,Shiyuan,Zhang,Zhiying,Guan,Yu,et al. Quantitative comparison of lung physiological parameters in single and multiple breathhold with hyperpolarized xenon magnetic resonance[J]. Biomedical Physics & Engineering Express,2016,2(5).
APA Liu,Shiyuan.,Zhang,Zhiying.,Guan,Yu.,Li,Haidong.,Zhao,Xiuchao.,...&Sun,Xianping.(2016).Quantitative comparison of lung physiological parameters in single and multiple breathhold with hyperpolarized xenon magnetic resonance.Biomedical Physics & Engineering Express,2(5).
MLA Liu,Shiyuan,et al."Quantitative comparison of lung physiological parameters in single and multiple breathhold with hyperpolarized xenon magnetic resonance".Biomedical Physics & Engineering Express 2.5(2016).

入库方式: OAI收割

来源:武汉物理与数学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。