Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification
文献类型:期刊论文
作者 | Wang, Yanli1; Chen, Quan2; Xian, Mo2; Nian, Rui2; Xu, Fei1 |
刊名 | AMB EXPRESS |
出版日期 | 2018-06-01 |
卷号 | 8 |
ISSN号 | 2191-0855 |
关键词 | Monoclonal Antibody Electronegative Multimodal Non-affinity Purification Cost-savings |
DOI | 10.1186/s13568-018-0622-3 |
文献子类 | Article |
英文摘要 | In recent studies, electronegative multimodal chromatography with Eshmuno HCX was demonstrated to be a highly promising recovery step for direct immunoglobulin G (IgG) capture from undiluted cell culture fluid. In this study, the binding properties of HCX to IgG at different pH/salt combinations were systematically studied, and its purification performance was significantly enhanced by lowering the washing pH and conductivity after high capacity binding of IgG under its optimal conditions. A single polishing step gave an end-product with non-histone host cell protein (nh-HCP) below 1 ppm, DNA less than 1 ppb, which aggregates less than 0.5% and an overall IgG recovery of 86.2%. The whole non-affinity chromatography based two-column-step process supports direct feed loading without buffer adjustment, thus extraordinarily boosting the overall productivity and cost-savings. |
WOS关键词 | CATION-EXCHANGE CHROMATOGRAPHY ; HYDROPHOBIC INTERACTION CHROMATOGRAPHY ; PROTEIN-A CHROMATOGRAPHY ; CELL-CULTURE FLUID ; MONOCLONAL-ANTIBODIES ; VOID-EXCLUSION ; CHROMATIN ; PERFORMANCE ; PH ; CLEARANCE |
WOS研究方向 | Biotechnology & Applied Microbiology |
语种 | 英语 |
出版者 | BIOMED CENTRAL LTD |
WOS记录号 | WOS:000433978500004 |
资助机构 | National Natural Science Foundation of China(21676286) |
源URL | [http://ir.qibebt.ac.cn/handle/337004/11391] |
专题 | 中国科学院青岛生物能源与过程研究所 |
通讯作者 | Nian, Rui; Xu, Fei |
作者单位 | 1.Jilin Univ, Coll Life Sci, Changchun, Jilin, Peoples R China 2.Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, CAS Key Lab Biobased Mat, Qingdao, Peoples R China |
推荐引用方式 GB/T 7714 | Wang, Yanli,Chen, Quan,Xian, Mo,et al. Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification[J]. AMB EXPRESS,2018,8. |
APA | Wang, Yanli,Chen, Quan,Xian, Mo,Nian, Rui,&Xu, Fei.(2018).Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification.AMB EXPRESS,8. |
MLA | Wang, Yanli,et al."Application of enhanced electronegative multimodal chromatography as the primary capture step for immunoglobulin G purification".AMB EXPRESS 8(2018). |
入库方式: OAI收割
来源:青岛生物能源与过程研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。