Life Test of the InGaAs Focal Plane Arrays Detector for Space Applications

文献类型:会议论文

作者Zhu XL; Zhang HY; Li X; Huang ZC; Gong HM
出版日期2017
DOI10.1117/12.2273591
英文摘要The short-wavelength infrared (SWIR) InGaAs focal plane array (FPA) detector consists of infrared detector chip readout integrated circuit (ROIC) and flip-chip bonding interconnection by Indium bump. In order to satisfy space application requirements for failure rates or Mean Time to Failure (MTTF) which can only be demonstrated with the large number of detectors manufactured the single pixel in InGaAs FPAs was chosen as the research object in this paper. The constant-stress accelerated life tests were carried out at 70 degrees C 80 degrees C 90 degrees C and 100 degrees C. The failed pixels increased gradually during more than 14000 hours at each elevated temperatures. From the random failure data the activation energy was estimated to be 0.46eV and the average lifetime of a single pixel in InGaAs FPAs was estimated to be longer than 1E+7h at the practical operating temperature (5 degrees C).
语种英语
源URL[http://202.127.2.71:8080/handle/181331/12094]  
专题上海技术物理研究所_上海技物所
作者单位Shanghai Inst Tech Phys
推荐引用方式
GB/T 7714
Zhu XL,Zhang HY,Li X,et al. Life Test of the InGaAs Focal Plane Arrays Detector for Space Applications[C]. 见:.

入库方式: OAI收割

来源:上海技术物理研究所

浏览0
下载0
收藏0