Effects of the driving voltage waveform on the performance of the Stirling-type pulse tube cryocooler driven by the moving-coil linear compressor
文献类型:期刊论文
作者 | Tan J; Dang HZ |
刊名 | INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID
![]() |
出版日期 | 2017 |
卷号 | 75页码:239-249 |
DOI | 10.1016/j.ijrefrig.2016.12.017 |
英文摘要 | The effects of three typical waveforms, namely, sine, trapezoid and smeared sine, on the performance of the Stirling-type pulse tube cryocooler (SPTC) driven by the moving-coil linear compressor are analyzed and studied experimentally. The results indicate that the dynamic pressure at the inlet of the cold finger has a weak relation with the driving voltage waveform, but the latter plays an important role in affecting both the motor efficiency and the SPTC cooling performance. In the tested range, either the cooling efficiency or the motor efficiency under the smeared sine waveform is the highest, while that under the sine waveform is the lowest. Moreover, given that the input power is below 30W, the motor efficiencies under both smeared sine and trapezoid waveforms exceed 90%, which suggests a promising approach to achieve a linear compressor with a very high motor efficiency by optimizing the voltage waveform. (C) 2016 Elsevier Ltd and IIR. All rights reserved. |
源URL | [http://202.127.2.71:8080/handle/181331/12286] ![]() |
专题 | 上海技术物理研究所_上海技物所 |
作者单位 | Shanghai Inst Tech Phys |
推荐引用方式 GB/T 7714 | Tan J,Dang HZ. Effects of the driving voltage waveform on the performance of the Stirling-type pulse tube cryocooler driven by the moving-coil linear compressor[J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID,2017,75:239-249. |
APA | Tan J,&Dang HZ.(2017).Effects of the driving voltage waveform on the performance of the Stirling-type pulse tube cryocooler driven by the moving-coil linear compressor.INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID,75,239-249. |
MLA | Tan J,et al."Effects of the driving voltage waveform on the performance of the Stirling-type pulse tube cryocooler driven by the moving-coil linear compressor".INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID 75(2017):239-249. |
入库方式: OAI收割
来源:上海技术物理研究所
浏览0
下载0
收藏0
其他版本