A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol
文献类型:期刊论文
作者 | Fu, Li1; Wang, Aiwu2,3; Lai, Guosong4; Lin, Cheng-Te5; Yu, Jinhong5; Yu, Aimin4,6; Liu, Zhong7![]() |
刊名 | MICROCHIMICA ACTA
![]() |
出版日期 | 2018-02-01 |
卷号 | 185期号:2 |
关键词 | Low Temperature Synthesis Surface Functional Group Electrode Modification Cyclic Voltammetry Differential Pulse Voltammetry Pharmaceutical Analysis H2o2 Disinfector Electrochemical Sensor Nanomaterial |
文献子类 | Article |
英文摘要 | Nitrogen doped carbon dots (NCDs) were synthesized using a low temperature approach and used to modify a glassy carbon electrode (GCE) via dipping. The oxygen groups on the surface of the NCDs, and the charge delocalization of the NCDs warrant an excellent electrocatalytic activity of the GCE toward oxidation of paracetamol (PA) and reduction of H2O2 center dot PA and H2O2 were detected at 0.34 V and -0.4 V (both vs. Ag/AgCl) using differential pulse voltammetry and amperometric I-T measurement, respectively. The modified GCE has a linear response to PA in the 0.5 to 600 mu M concentration range, and to H2O2 in the 0.05 mu M to 2.25 mM concentration range. The detection limits are 157 nM and 41 nM, respectively. In our perception, the modified GCE holds promise for stable, selective and sensitive determination of PA and H2O2 in pharmaceutical analysis. |
WOS关键词 | GRAPHENE QUANTUM DOTS ; ELECTROCHEMICAL SENSOR ; GOLD NANOPARTICLES ; NANOTUBES ; DOPAMINE ; NANOCOMPOSITES ; HYDROQUINONE ; NANOFIBERS ; REDUCTION ; CATECHOL |
WOS研究方向 | Chemistry |
语种 | 英语 |
WOS记录号 | WOS:000424287200026 |
源URL | [http://ir.isl.ac.cn/handle/363002/6422] ![]() |
专题 | 青海盐湖研究所_青海盐湖研究所知识仓储 青海盐湖研究所_盐湖资源与化学实验室 |
作者单位 | 1.Hangzhou Dianzi Univ, Coll Mat & Environm Engn, Hangzhou 310018, Zhejiang, Peoples R China 2.City Univ Hong Kong, COSDAF, Hong Kong, Hong Kong, Peoples R China 3.City Univ Hong Kong, Dept Phys & Mat Sci, Hong Kong, Hong Kong, Peoples R China 4.Hubei Normal Univ, Dept Chem, Hubei Key Lab Pollutant Anal & Reuse Technol, Hubei Collaborat Innovat Ctr Rare Met Chem, Huangshi 435002, Peoples R China 5.Chinese Acad Sci, Ningbo Inst Mat Technol & Engn, Zhejiang Key Lab Marine Mat & Protect Technol, Key Lab Marine Mat & Related Technol, Ningbo 315201, Zhejiang, Peoples R China 6.Swinburne Univ Technol, Fac Sci Engn & Technol, Dept Chem & Biotechnol, Hawthorn, Vic 3122, Australia 7.Chinese Acad Sci, Qinghai Inst Salt Lakes, Key Lab Comprehens & Highly Efficient Utilizat Sa, Xining 810008, Qinghai, Peoples R China 8.Qinghai Univ, State Key Lab Plateau Ecol & Agr, Xining 810016, Qinghai, Peoples R China |
推荐引用方式 GB/T 7714 | Fu, Li,Wang, Aiwu,Lai, Guosong,et al. A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol[J]. MICROCHIMICA ACTA,2018,185(2). |
APA | Fu, Li.,Wang, Aiwu.,Lai, Guosong.,Lin, Cheng-Te.,Yu, Jinhong.,...&Su, Weitao.(2018).A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol.MICROCHIMICA ACTA,185(2). |
MLA | Fu, Li,et al."A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol".MICROCHIMICA ACTA 185.2(2018). |
入库方式: OAI收割
来源:青海盐湖研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。