英文摘要In this study, a method for high-precision measurement of Hg isotope ratios by multiple collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) with on-line Hg reduction technique was developed. The procedure was evaluated to obtain high-precision measurements that were good enough to significantly detect the anticipated small differences in Hg isotope compositions in natural samples. Typically, internal precision was better than 0.02%° (1 RSE) on all Hg ratios investigated. The external reproducibility for standard NIST SRM3133 and UM-Almadén secondary solution, nature samples were 0.06%° (2SD) and 0.10%° (2SD) over a period of 7 months, respectively. The extent of fractionation has been investigated in a series of natural samples from different locations in China. The ratio 202Hg/198Hg expressed as δ values (per mil deviations relative to NIST SRM 3133 Hg standard solution) displayed differences from –3.48%° to 0.633%°. These results indicated a wide perspective application of tracing Hg in the environment.
学科主题环境地球化学
语种英语
公开日期2017-12-19
源URL[http://ir.gyig.ac.cn:8080/handle/352002/6805]  
专题地球化学研究所_环境地球化学国家重点实验室_环境地球化学国家重点实验室_期刊论文
地球化学研究所_环境地球化学国家重点实验室
推荐引用方式
GB/T 7714
Delphine Foucher,Wen-Fang SHI,Zhi-Qi ZHAO,et al. High Precision Determination of Mercury Isotope Ratios Using Online Mercury Vapor Generation System Coupled with Multi-collector Inductively Coupled Plasma-Mass Spectrometry[J]. Chinese Journal of Analytical Chemistry,2010,38(7):929-934.
APA Delphine Foucher,Wen-Fang SHI,Zhi-Qi ZHAO,Jing WANG,Xin-Bin FENG,&Run-Sheng YIN.(2010).High Precision Determination of Mercury Isotope Ratios Using Online Mercury Vapor Generation System Coupled with Multi-collector Inductively Coupled Plasma-Mass Spectrometry.Chinese Journal of Analytical Chemistry,38(7),929-934.
MLA Delphine Foucher,et al."High Precision Determination of Mercury Isotope Ratios Using Online Mercury Vapor Generation System Coupled with Multi-collector Inductively Coupled Plasma-Mass Spectrometry".Chinese Journal of Analytical Chemistry 38.7(2010):929-934.

入库方式: OAI收割

来源:地球化学研究所

浏览0
下载0
收藏0
其他版本

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。