Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references
文献类型:期刊论文
| 作者 | Yuxu Zhang; Xiangkun Zhu; Hanjie Wen; Jean Carignan; Christophe Cloquet |
| 刊名 | Journal of Analytical Atomic Spectrometry
![]() |
| 出版日期 | 2010 |
| 卷号 | 25期号:5页码:716-721 |
| 英文摘要 | We report the isotopic composition of five molybdenum (Mo) standard reference solutions and four fractions from one of these solutions eluted through anion resin column relative to a sixth reference solution. The reference solutions were National Institute of Standards and Technology (NIST) SRM 3134 (lot#891307), Johnson Matthey Specpure (JMC)-Mo Sie (lot #602332B), JMC-Mo Wen (lot#13989C), Merck (lot#170334), Sigma-Aldrich (lot#207306) and Prolabo. Measurements were conducted using Isoprobe multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS) at the Centre de Recherches Pétrographiques et Géochimiques (France) and Nu Plasma MC-ICP-MS at either the Ecole Normale Supérieure de Lyon (France) or the Laboratory of Isotope Geology in the Ministry of Land and Resources (China). The sample-standard bracketing method was employed to correct the mass bias for Mo isotopes during instrumental measurement. Except for the Merck Mo solution, all the Mo solutions were identical in isotopic composition within error. Although the JMCMo solution has been used as the internal reference material by various groups, uncertainty may still occur with different lot numbers and availability might be limited. Here, we propose the NIST 3134 Mo solution as a new candidate for delta zero reference material, used for reporting Mo isotopic composition of natural samples. Isotopic compositions for four eluted fractions of the Sigma-Aldrich Mo solution were 2.18‰, 0.98‰, −1.10‰ and −1.95‰ for δ97/95Mo relative to the NIST Mo standard. These values span the range of reported isotopic compositions for natural terrestrial and experimental samples (approximately −0.5‰ to 1.6‰ for δ97/95Mo). We propose these eluted fractions to be used as a secondary reference for Mo isotope measurements. Mo solutions are available at CRPG upon request. |
| 学科主题 | 矿床地球化学 |
| 语种 | 英语 |
| 公开日期 | 2017-12-20 |
| 源URL | [http://ir.gyig.ac.cn:8080/handle/352002/6846] ![]() |
| 专题 | 地球化学研究所_矿床地球化学国家重点实验室_矿床地球化学国家重点实验室_期刊论文 |
| 推荐引用方式 GB/T 7714 | Yuxu Zhang,Xiangkun Zhu,Hanjie Wen,et al. Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references[J]. Journal of Analytical Atomic Spectrometry,2010,25(5):716-721. |
| APA | Yuxu Zhang,Xiangkun Zhu,Hanjie Wen,Jean Carignan,&Christophe Cloquet.(2010).Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references.Journal of Analytical Atomic Spectrometry,25(5),716-721. |
| MLA | Yuxu Zhang,et al."Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references".Journal of Analytical Atomic Spectrometry 25.5(2010):716-721. |
入库方式: OAI收割
来源:地球化学研究所
浏览0
下载0
收藏0
其他版本
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。

